BACKGROUND CORRECTION DEVICE FOR ENHANCED ELEMENT-SELECTIVE GAS-CHROMATOGRAPHIC DETECTION BY ATOMIC-EMISSION SPECTROSCOPY

被引:5
作者
FARNSWORTH, PB
WU, MG
TACQUARD, M
LEE, ML
机构
关键词
ATOMIC EMISSION SPECTROSCOPY; ELEMENT-SELECTIVE GAS CHROMATOGRAPHIC DETECTION; BACKGROUND CORRECTION; SULFUR DETECTION;
D O I
10.1366/000370294774368929
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A two-channel optical device has been used to enhance the selectivity of sulfur detection based on emission from a radio-frequency helium plasma coupled to a gas chromatograph (GC). A wedge prism was used to split collimated emission from the plasma into two components with an angular separation of nine degrees. The two beams were then transmitted through a narrow-band interference filter at center wavelengths of 918.0 and 921.3 nm. Background radiation at 918.0 nm was scaled and subtracted from the combined signal and background radiation at 921.3 nm to give a net sulfur emission signal that was insensitive to the passage of sulfur-free species through the plasma. The performance of the device was characterized in use with a radio-frequency plasma attached to a comprehensive SFE/GC system as well as to a conventional capillary gas chromatograph. The detection limit and selectivity for the SFE/GC system were 17 pg s-1 and 23,000 respectively. The detection limit and selectivity for the conventional GC were 0.2 pg s-1 and 12,000, respectively.
引用
收藏
页码:742 / 746
页数:5
相关论文
共 13 条
[1]  
CHANG HCK, 1990, POLYCYCL AROMAT COMP, V1, P251
[2]   BACKGROUND AND BACKGROUND CORRECTION IN ANALYTICAL ATOMIC SPECTROMETRY .1. EMISSION-SPECTROMETRY A TUTORIAL REVIEW [J].
DAWSON, JB ;
SNOOK, RD ;
PRICE, WJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (04) :517-537
[3]   HIGH-SPEED, THERMALLY MODULATED SFE GC FOR THE ANALYSIS OF VOLATILE ORGANIC-COMPOUNDS IN SOLID MATRICES [J].
LIU, ZY ;
FARNSWORTH, PB ;
LEE, ML .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1992, 4 (03) :199-208
[4]  
Pearse RWB, 1976, IDENTIFI CATION MOL, V4th, DOI DOI 10.1007/978-94-009-5758-9
[5]  
PLATZER B, 1992, ACS S SER, V479, pCH9
[6]   CHARACTERIZATION OF NEAR-INFRARED ATOMIC EMISSION FROM A RADIOFREQUENCY PLASMA FOR SELECTIVE DETECTION IN CAPILLARY GAS-CHROMATOGRAPHY [J].
SKELTON, RJ ;
MARKIDES, KE ;
LEE, ML ;
FARNSWORTH, PB .
APPLIED SPECTROSCOPY, 1990, 44 (05) :853-857
[7]   ELEMENT SELECTIVE DETECTION AFTER SUPERCRITICAL FLUID CHROMATOGRAPHY USING A RADIO-FREQUENCY PLASMA DETECTOR [J].
SKELTON, RJ ;
FARNSWORTH, PB ;
MARKIDES, KE ;
LEE, ML .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1815-1821
[8]  
SKELTON RJ, 1988, HRC-J HIGH RES CHROM, V11, P75
[9]  
Striganov A. R., 1966, TABLITSY SPEKTRALNYK
[10]   CHARACTERIZATION OF A COMPUTERIZED PHOTODIODE ARRAY SPECTROMETER FOR GAS-CHROMATOGRAPHY ATOMIC EMISSION-SPECTROMETRY [J].
SULLIVAN, JJ ;
QUIMBY, BD .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :1034-1043