HIGH-SENSITIVITY POINT MONITORING OF OZONE, AND HIGH-RESOLUTION SPECTROSCOPY OF THE NU-3 BAND OF OZONE USING A TUNABLE SEMICONDUCTOR DIODE-LASER

被引:37
作者
ELSHERBINY, M
BALLIK, EA
SHEWCHUN, J
GARSIDE, BK
REID, J
机构
[1] McMaster University, Department of Engineering Physics, Hamilton, ON
来源
APPLIED OPTICS | 1979年 / 18卷 / 08期
关键词
D O I
10.1364/AO.18.001198
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Accurate measurements of the wavenumbers of more than 100 lines in the ν3 band of ozone have been made using a tunable semiconductor diode laser and a temperature-stabilized germanium etalon.The accuracy for the line centers is estimated to be within 3–10 MHz and compares well with the accuracy attained using more complicated heterodyne techniques.The relevance of these results to ozone monitoring instruments based on CO2 lasers is discussed.The tunability of the diode laser is also exploited to monitor ambient concentrations of ozone in the presence of interfering molecular species.A detection sensitivity of ˜0.5 ppb of ozone is demonstrated.© 1979 Optical Society of America.
引用
收藏
页码:1198 / 1203
页数:6
相关论文
共 25 条
  • [1] STRATOSPHERIC OZONE MEASUREMENT WITH AN INFRARED HETERODYNE SPECTROMETER
    ABBAS, MM
    KOSTIUK, T
    MUMMA, MJ
    BUHL, D
    KUNDE, VG
    BROWN, LW
    [J]. GEOPHYSICAL RESEARCH LETTERS, 1978, 5 (04) : 317 - 320
  • [2] IR AND MICROWAVE HIGH-RESOLUTION SPECTRUM OF V3-BAND OF OZONE
    BARBE, A
    SECROUN, C
    JOUVE, P
    MONNANTEUIL, N
    DEPANNEMAECKER, JC
    DUTERAGE, B
    BELLET, J
    PINSON, P
    [J]. JOURNAL OF MOLECULAR SPECTROSCOPY, 1977, 64 (03) : 343 - 364
  • [3] HIGH-RESOLUTION SPECTRAL MEASUREMENT OF HNO3 11.3-MUM BAND USING TUNABLE DIODE-LASERS
    BROCKMAN, P
    BAIR, CH
    ALLARIO, F
    [J]. APPLIED OPTICS, 1978, 17 (01): : 91 - 100
  • [4] DIODE-LASER SPECTRA WITH SIMULTANEOUS FREQUENCY CALIBRATION
    CHRAPLYVY, AR
    [J]. APPLIED OPTICS, 1978, 17 (17): : 2674 - 2675
  • [5] REFRACTIVE-INDEX MEASUREMENTS OF A GERMANIUM SAMPLE
    EDWIN, RP
    DUDERMEL, MT
    LAMARE, M
    [J]. APPLIED OPTICS, 1978, 17 (07) : 1066 - 1068
  • [6] WAVENUMBER CALIBRATION OF TUNABLE DIODE-LASERS USING ETALONS
    FLICKER, H
    ALDRIDGE, JP
    FILIP, H
    NERESON, NG
    REISFELD, MJ
    WEBER, WH
    [J]. APPLIED OPTICS, 1978, 17 (06): : 851 - 852
  • [7] DETERMINATION OF LASER LINE FREQUENCIES AND VIBRATIONAL-ROTATIONAL CONSTANTS OF C-12O-18(2), C-13O-16(2), AND C-13O-18(2) ISOTOPES FROM MEASUREMENTS OF CW BEAT FREQUENCIES WITH FAST HGCDTE PHOTODIODES AND MICROWAVE FREQUENCY COUNTERS
    FREED, C
    ROSS, AHM
    ODONNELL, RG
    [J]. JOURNAL OF MOLECULAR SPECTROSCOPY, 1974, 49 (03) : 439 - 453
  • [8] ABSOLUTE FREQUENCY CALIBRATION OF CO2 ISOTOPE LASER TRANSITIONS
    FREED, C
    ODONNELL, RG
    ROSS, AHM
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1976, 25 (04) : 431 - 437
  • [9] Precision measurements of NH3 spectral lines near 11 mu m using the infrared heterodyne technique
    Hillman, J.
    Kostiuk, Theodor
    Buhl, David
    Faris, J.
    Novaco, J.
    Mumma, M.
    [J]. OPTICS LETTERS, 1977, 1 (03) : 81 - 83
  • [10] CHLOROFLUOROCARBON-OZONE THEORY - SCIENTIFIC STATUS-REPORT
    JESSON, JP
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1977, 16 (08): : 513 - 519