PROLONGED T1 IN PATIENTS WITH LIVER-CIRRHOSIS - AN INVIVO MRI STUDY

被引:46
作者
THOMSEN, C
CHRISTOFFERSEN, P
HENRIKSEN, O
JUHL, E
机构
[1] Department of Magnetic Resonance, Hvidovre Hospital, University of Copenhagen, Copenhagen
[2] Department of Pathology, Hvidovre Hospital, University of Copenhagen, Copenhagen
[3] Department of Hepatology, Hvidovre Hospital, University of Copenhagen, Copenhagen
关键词
Liver cirrhosis; Magnetic resonance; Relaxation times; T[!sub]1[!/sub; T[!sub]2[!/sub;
D O I
10.1016/0730-725X(90)90137-Q
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fifteen patients with liver cirrhosis and two control groups were examined. The first control group consisted of 7 healthy volunteers, and the second group of 17 patients with nonfocal liver diseases. The T1 and T2 relaxation times were calculated from signal intensities read out from a region of interest centrally located in the liver. T1 relaxation time was longer in the patients with liver cirrhosis than in the two reference groups. Ten patients had a liver biopsy taken prior to the MRI study. No correlation was found between histophatology and the measured relaxation times. © 1990.
引用
收藏
页码:599 / 604
页数:6
相关论文
共 37 条
  • [1] Barthwal, Hohn-Berlage, Gersonde, In vitro Troton T<sub>1</sub> and T<sub>2</sub> studies on rat liver: Analysis of multiexponential relaxation processes, Magn. Reson. Med., 3, pp. 863-875, (1986)
  • [2] Bernadino, Small, Goldstein, Sewel, Sones, Gedgaudas-McClees, Galambos, Wenger, Casarella, Multiple NMR T2 relaxation values in human liver tissue, American Journal of Roentgenology, 141, pp. 1203-1208, (1983)
  • [3] Bernadino, Chaloupka, Malko, Chezmar, Nelson, Are hepatic and muscle T2 values different at 0.5 and 1.5 Tesla?, Magn. Reson. Imaging, 7, pp. 361-367, (1989)
  • [4] Bottomley, Hardy, Argersinger, Allen-Moore, A review of 1H nuclear magnetic resonance relaxation in pathology: Are T<sub>1</sub> and T<sub>2</sub> diagnostic?, Med. Phys., 14, pp. 1-37, (1987)
  • [5] Bottomley, Foster, Argersinger, Pfeifer, A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1–100 MHz: Dependence on tissue type, NMR frequency, temperature, species, excision, and age, Med. Phys., 11, pp. 425-448, (1984)
  • [6] Damadian, Zaner, Hor, Dimaio, Human tumors by NMR, Physiol. Chem. Physics, 5, pp. 381-402, (1973)
  • [7] Doyle, Pennock, Banks, McDonnell, Bydder, Steiner, Young, Clarke, Pasmore, Gilderdale, Nuclear magnetic resonance imaging of the liver: Initial experience, AJAR, 138, pp. 193-200, (1982)
  • [8] Ebara, Ohto, Watanabe, Kimura, Saisho, Tsuchiya, Okuda, Arimizu, Kondo, Ikehira, Fukuda, Tateno, Diagnosis of small hepatocellular carcinoma: Correlation of MR imaging and tumor histologic studies, Radiology, 159, pp. 371-377, (1986)
  • [9] Edelman, Zhao, Liu, Wentz, Mattle, Finn, McArdle, MR angiography and dynamic flow evaluation of the portal venous system, AJR, 153, pp. 755-760, (1989)
  • [10] Ehman, Kjos, Hricak, Brasch, Higgins, Relative intensity of abdominal organs in MR images, Journal of Computer Assisted Tomography, 138, pp. 315-319, (1985)