ACCURACY AND REPRODUCIBILITY OF DUPLEX ULTRASOUND IMAGING IN A PHANTOM MODEL OF FEMORAL-ARTERY STENOSIS

被引:21
作者
WHYMAN, MR
HOSKINS, PR
LENG, GC
ALLAN, PL
DONNAN, PT
RUCKLEY, CV
FOWKES, FGR
机构
[1] ROYAL EDINBURGH & ASSOCIATED HOSP, DEPT MED PHYS, EDINBURGH EH3 9HB, MIDLOTHIAN, SCOTLAND
[2] ROYAL EDINBURGH & ASSOCIATED HOSP, DEPT RADIOL, EDINBURGH EH3 9HB, MIDLOTHIAN, SCOTLAND
[3] ROYAL EDINBURGH & ASSOCIATED HOSP, DEPT VASC SURG, EDINBURGH EH3 9HB, MIDLOTHIAN, SCOTLAND
关键词
D O I
10.1016/0741-5214(93)90153-D
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: The improvement of management strategies in patients with intermittent claudication might depend on a better understanding of the natural history of femoral atherosclerosis. The grading of stenoses, the monitoring of their progression, and the assessment of response to treatment are critically dependent on a method's accuracy and variability. Duplex ultrasound imaging provides a noninvasive way of measuring localized disease, but there has been relatively little objective evaluation of its accuracy and reproducibility. The aim of this study was to evaluate the accuracy and variability of duplex velocity ratio measurements of stenosis. Methods: In a laboratory flow model of the femoral artery, 14 concentric and eccentric stenoses were examined five times by three sonographers. Measurements were then repeated with a standardized technique in which Doppler angle and aperture position were fixed, giving a total of 420 measurements. Results: Velocity ratio showed good correlation with degree of stenosis, R2 = 0.996. Intraobserver variability was low, but interobserver variability was significant with more severe stenosis (p = 0.002, analysis of variance). Standardization of the technique did not improve accuracy or variability. The 95% confidence limit was +/- 20% for a single reading of velocity ratio for stenoses of > 50% diameter reduction. Conclusions: We conclude that duplex ultrasound imaging can be used to accurately grade arterial stenosis in this range, and the potential exists for noninvasive monitoring of the progression of preocclusive femoral atherosclerosis and its response to treatment. In addition, repeated measurements of velocity ratio over time should be made by the same observer.
引用
收藏
页码:524 / 530
页数:7
相关论文
共 22 条
[1]   ULTRASONIC DUPLEX ECHO-DOPPLER SCANNER [J].
BARBER, FE ;
BAKER, DW ;
NATION, AWC ;
STRANDNESS, DE ;
REID, JM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1974, BM21 (02) :109-113
[2]   A CRITICAL-STUDY OF ULTRASOUND DOPPLER SPECTRAL-ANALYSIS FOR DETECTING CAROTID DISEASE [J].
BROWN, PM ;
JOHNSTON, KW ;
KASSAM, M ;
COBBOLD, RSC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1982, 8 (05) :515-&
[3]   AN INVITRO MODEL AND ITS APPLICATION FOR THE STUDY OF CAROTID DOPPLER SPECTRAL BROADENING [J].
DOUVILLE, Y ;
JOHNSTON, KW ;
KASSAM, M ;
ZUECH, P ;
COBBOLD, RSC ;
JARES, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1983, 9 (04) :347-356
[4]  
EVENS RG, 1991, JAMA-J AM MED ASSOC, V265, P2382
[5]   REPRODUCIBILITY OF CAROTID-ARTERY DOPPLER FREQUENCY MEASUREMENTS [J].
FISCHER, M ;
ALEXANDER, K .
STROKE, 1985, 16 (06) :973-976
[6]  
HIRSHBERG A, 1988, Journal of the Royal College of Surgeons of Edinburgh, V33, P196
[7]   VELOCITY ESTIMATION USING DUPLEX SCANNERS [J].
HOSKINS, PR ;
MCDICKEN, WN .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (02) :195-198
[8]   A COMPUTER-CONTROLLED FLOW PHANTOM FOR GENERATION OF PHYSIOLOGICAL DOPPLER WAVEFORMS [J].
HOSKINS, PR ;
ANDERSON, T ;
MCDICKEN, WN .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (11) :1709-1717
[9]   NONINVASIVE MAPPING OF LOWER-LIMB ARTERIAL LESIONS [J].
JAGER, KA ;
PHILLIPS, DJ ;
MARTIN, RL ;
HANSON, C ;
ROEDERER, GO ;
LANGLOIS, YE ;
RICKETTS, HJ ;
STRANDNESS, DE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (03) :515-521
[10]   EMPIRICAL-FINDINGS RELATING SAMPLE VOLUME SIZE TO DIAGNOSTIC-ACCURACY IN PULSED DOPPLER CEREBROVASCULAR STUDIES [J].
KNOX, RA ;
PHILLIPS, DJ ;
BRESLAU, PJ ;
LAWRENCE, R ;
PRIMOZICH, J ;
STRANDNESS, DE .
JOURNAL OF CLINICAL ULTRASOUND, 1982, 10 (05) :227-232