ION MOBILITY SPECTROMETRY AS FLOW-INJECTION DETECTOR AND CONTINUOUS-FLOW MONITOR FOR ANILINE IN HEXANE AND WATER

被引:20
作者
EICEMAN, GA [1 ]
GARCIAGONZALEZ, L [1 ]
WANG, YF [1 ]
PITTMAN, B [1 ]
BURROUGHS, GE [1 ]
机构
[1] NIOSH,DIV PHYS SCI & ENGN,CINCINNATI,OH 45226
关键词
D O I
10.1016/0039-9140(92)80165-A
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ion mobility spectrometry (IMS) was used as a flow-injection detector to quantitatively examine the ionization chemistry of aniline in hexane. A 5-mu-l sample was vaporized at 15-90-sec intervals in a flowing air stream and analyzed with an IMS equipped with acetone reactant ion chemistry, ambient temperature drift tube and membrane-based inlet. Precision was 3-11% relative standard deviation for 1-100 ppm aniline in hexane with 90-sec injection intervals and detection limits were ca. 0.5 ppm with 5-mu-l injections. Matrix effects with amine and organic solvent mixtures were observed and corrected for low and medium proton affinity interferences with standard addition methods. Pronounced fouling of the IMS occurred when a continuous water flow was introduced for aqueous flow injection-IMS. Continuous water monitoring without degraded IMS performance was possible by sampling air flow through a Silastic tube immersed in an aqueous sample.
引用
收藏
页码:459 / 467
页数:9
相关论文
共 25 条
[1]   USE OF RESPIRATORY-CARDIOVASCULAR RESPONSES OF RAINBOW-TROUT (SALMO-GAIRDNERI) IN IDENTIFYING ACUTE TOXICITY SYNDROMES IN FISH .3. POLAR NARCOTICS [J].
BRADBURY, SP ;
HENRY, TR ;
NIEMI, GJ ;
CARLSON, RW ;
SNARSKI, VM .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1989, 8 (03) :247-261
[2]   AN ALTERNATIVE METHOD FOR GAS-CHROMATOGRAPHIC DETERMINATION OF VOLATILE ORGANIC-COMPOUNDS IN WATER [J].
COUTANT, RW ;
KEIGLEY, GW .
ANALYTICAL CHEMISTRY, 1988, 60 (22) :2536-2537
[3]  
DAM R, PLASMA CHROMATOGRAPH
[4]  
EICEMAN G A, 1991, Critical Reviews in Analytical Chemistry, V22, P471, DOI 10.1080/10408349108055024
[5]   MONITORING OF AIRBORNE ORGANIC VAPORS USING ION MOBILITY SPECTROMETRY [J].
EICEMAN, GA ;
SNYDER, AP ;
BLYTH, DA .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1990, 38 (03) :415-425
[6]   SCREENING OF SOLID COMMERCIAL PHARMACEUTICALS USING ION MOBILITY SPECTROMETRY [J].
EICEMAN, GA ;
BLYTH, DA ;
SHOFF, DB ;
SNYDER, AP .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1374-1379
[7]   FRAGMENTATION OF BUTYL ACETATE ISOMERS IN THE DRIFT REGION OF AN ION MOBILITY SPECTROMETER [J].
EICEMAN, GA ;
SHOFF, DB ;
HARDEN, CS ;
SNYDER, AP .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1988, 85 (03) :265-275
[8]   CHRONIC TOXICITY OF ANILINE AND 2,4-DICHLOROPHENOL TO DAPHNIA-MAGNA STRAUS [J].
GERSICH, FM ;
MILAZZO, DP .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1988, 40 (01) :1-7
[9]   ELECTROCHEMICAL THERMOSPRAY MASS-SPECTROMETRY [J].
HAMBITZER, G ;
HEITBAUM, J .
ANALYTICAL CHEMISTRY, 1986, 58 (06) :1067-1070
[10]  
HARDEN CS, COMMUNICATION