THE SAFETY AND PHARMACOKINETICS IN ADULT SUBJECTS OF AN INTRAVENOUSLY ADMINISTERED TC-99M-LABELED 17 AMINO-ACID PEPTIDE (CYT-379)

被引:15
作者
BENHAIM, S
KAHN, D
WEINER, GJ
MADSEN, MT
WAXMAN, AD
WILLIAMS, CM
CLARKEPEARSON, DL
COLEMAN, RE
MAGUIRE, RT
机构
[1] UNIV IOWA,COLL MED,DEPT RADIOL,DIV NUCL MED,IOWA CITY,IA 52242
[2] UNIV IOWA,COLL MED,DEPT INTERNAL MED,IOWA CITY,IA 52242
[3] CEDARS SINAI MED CTR,DEPT RADIOL,LOS ANGELES,CA 90048
[4] DUKE UNIV,MED CTR,DEPT OBSTET & GYNECOL,DURHAM,NC 27710
[5] DUKE UNIV,MED CTR,DEPT RADIOL,DURHAM,NC 27710
[6] CYTOGEN INC,PRINCETON,NJ
来源
NUCLEAR MEDICINE AND BIOLOGY | 1994年 / 21卷 / 02期
关键词
D O I
10.1016/0969-8051(94)90001-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A phase I study was designed to evaluate the safety and pharmacokinetics of a novel platelet reactive peptide, peptide acetyl-SYGRGDVRGDFKCTCCA-amide (CYT-379), which binds to the fibrinogen receptor of activated platelets and also binds to Tc-99m. Eleven subjects with suspected deep venous thrombosis had 0.1, 0.5 or 1.0 mg of the peptide infused intravenously. Pharmacokinetics were determined by assaying blood samples in 6 of the 11 subjects and by urine sampling in 5 of these 6 subjects. Plasma and whole blood time-activity curves demonstrated an initial fast component with half-time clearance of 0.2 +/- 0.01 and 0.2 +/- 0.02 h and a slow component with half-time clearance of 2.8 +/- 0.3 and 2.7 +/- 0.2 h (mean +/- SEM for plasma and whole blood, respectively). Urine clearance was 22.6 +/- 3.3 and 10.8 +/- 1.6 mL/min when normalized to body surface area. The cumulative excretion of Tc-99m-CYT-379 in the urine was 16.6 +/- 3.6, 45.6 +/- 16.9 and 45.6 +/- 1.8% of the administered dose over 0-2, 0-12 and 0-24 h after radiopharmaceutical injection, respectively. Images obtained in 11 subjects immediately, at 1-2, and 4-6 h after injection were evaluated for abnormalities and were compared with duplex Doppler ultrasonography. Tc-99m-CYT-379 images were positive in only 3 of 7 subjects who had a positive duplex Doppler examination in at least one lower extremity. One subject with negative duplex Doppler had also negative Tc-99m-CYT-379 scintigraphy. One subject with negative scintigraphy and two other subjects with positive scintigraphy had no other imaging studies of the deep venous system performed. No adverse reactions were observed during or after the infusion of Tc-99m-CYT-379. Tc-99m-CYT-379 appears to be a safe radiopharmaceutical and demonstrates rapid clearance from plasma in human subjects.
引用
收藏
页码:131 / 142
页数:12
相关论文
共 36 条
[1]   CONTRAST VENOGRAPHY OF THE LEG - DIAGNOSTIC EFFICACY, TOLERANCE, AND COMPLICATION RATES WITH IONIC AND NONIONIC CONTRAST-MEDIA [J].
BETTMANN, MA ;
ROBBINS, A ;
BRAUN, SD ;
WETZNER, S ;
DUNNICK, NR ;
FINKELSTEIN, J .
RADIOLOGY, 1987, 165 (01) :113-116
[2]  
BOH LE, 1982, CLIN CLERKSHIP MANUA
[3]  
CARRASQUILLO JA, 1988, J NUCL MED, V29, P1022
[4]  
CARTER C, 1987, HEMOSTASIS THROMBOSI, P1185
[5]   ADEQUACY OF LOWER-LIMB VENOUS OPACIFICATION - COMPARISON OF SUPINE AND UPRIGHT PHLEBOGRAPHY [J].
COEL, MN .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 134 (01) :163-165
[6]  
COLEMAN RE, 1978, J NUCL MED, V16, P370
[7]  
Comerota A J, 1988, Ann Vasc Surg, V2, P406, DOI 10.1016/S0890-5096(06)60826-1
[8]   RECURRENT DEEP VENOUS THROMBOSIS - LIMITATIONS OF US [J].
CRONAN, JJ ;
LEEN, V .
RADIOLOGY, 1989, 170 (03) :739-742
[9]   IN-111 PLATELET SCINTIGRAPHY FOR THE DIAGNOSIS OF ACUTE VENOUS THROMBOSIS [J].
EZEKOWITZ, MD ;
POPE, CF ;
SOSTMAN, HD ;
SMITH, EO ;
GLICKMAN, M ;
RAPOPORT, S ;
SNIDERMAN, KW ;
FRIEDLAENDER, G ;
PELKER, RR ;
TAYLOR, FB ;
ZARET, BL .
CIRCULATION, 1986, 73 (04) :668-674
[10]   DEEP-VEIN THROMBOSIS IN PATIENTS WITH FRACTURES OF FEMORAL NECK [J].
FIELD, ES ;
CRELLIN, RQ ;
NICOLAIDES, AN ;
KAKKAR, VV .
BRITISH JOURNAL OF SURGERY, 1972, 59 (05) :377-+