SEPARATION OF STYRENE-BUTYL METHACRYLATE COPOLYMERS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:7
作者
OGINO, K
MARUO, T
SATO, H
机构
[1] Department of Material Systems Engineering, Faculty of Technology, Tokyo University of Agriculture and Technology, Koganei, Tokyo
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1994年 / 17卷 / 14-15期
关键词
D O I
10.1080/10826079408013189
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Styrene/n-butyl methacrylate (S/nBMA) and styrene/t-butyl methacrylate (S/tBMA) copolymers were separated by chemical composition using HPLC. In the case of normal phase HPLC using acrylamide gel or acrylonitrile gel as a stationary phase, S/nBMA and S/tBMA copolymers were separated by chemical composition. S/BMA copolymers were eluted from higher styrene content using dichloromethane/n-hexane as an eluent, while with the opposite elution order with tetrahydrofuran/iso-octane eluent, The difference of the elution order is explained by hydrogen bondings between the gel and the sample or eluent. In reversed phase HPLC using a styrene column and nonpolar eluent such as dichloromethane/acetonitrile, S/BMA copolymers were eluted from lower styrene content using any kind of eluent examined. On the other hand, an octadecyl methacrylate column provided no separation based on the composition. The separation using the styrene column was ascribed to the specific interaction of the phenyl groups in the sample and the gel. By the comparison of the content of good solvent in an eluent and clouds point of copolymers, it was confirmed that separation was done by adsorption mechanism for both of normal and reversed phase liquid chromatography.
引用
收藏
页码:3025 / 3041
页数:17
相关论文
共 33 条
[1]   HIGH-PERFORMANCE ADSORPTION CHROMATOGRAPHY OF POLYMERS - SEPARATION OF STYRENE ACRYLONITRILE COPOLYMERS ON CN SILICA [J].
DANIELEWICZ, M ;
KUBIN, M ;
VOZKA, S .
JOURNAL OF APPLIED POLYMER SCIENCE, 1982, 27 (09) :3629-3631
[2]   HIGH-PERFORMANCE COLUMN ADSORPTION CHROMATOGRAPHY OF RANDOM CO-POLYMERS STYRENE-ACRYLICS [J].
DANIELEWICZ, M ;
KUBIN, M .
JOURNAL OF APPLIED POLYMER SCIENCE, 1981, 26 (03) :951-956
[3]   OPEN TUBULAR COLUMNS AND NON-POROUS PACKINGS IN COPOLYMER HPLC ANALYSIS [J].
GLOCKNER, G ;
VANDENBERG, JHM .
CHROMATOGRAPHIA, 1987, 24 :233-240
[4]  
GLOCKNER G, 1983, MAKROMOL CHEM-RAPID, V4, P529
[5]   NORMAL-PHASE AND REVERSED-PHASE SEPARATION OF COPOLYMERS PREPARED FROM STYRENE AND ETHYL-METHACRYLATE [J].
GLOCKNER, G .
JOURNAL OF CHROMATOGRAPHY, 1987, 403 :280-284
[6]   GRADIENT ELUTION CHROMATOGRAPHY OF POLYMERS ON REVERSED-PHASE COLUMNS WITH TETRAHYDROFURAN AS AN ELUENT COMPONENT [J].
GLOCKNER, G ;
VANDENBERG, JHM .
CHROMATOGRAPHIA, 1984, 19 :55-61
[7]   COPOLYMER FRACTIONATION BY GRADIENT HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GLOCKNER, G ;
VANDENBERG, JHM .
JOURNAL OF CHROMATOGRAPHY, 1987, 384 :135-144
[8]   INVESTIGATION OF COPOLYMERS OF STYRENE AND ETHYL-METHACRYLATE BY SIZE EXCLUSION CHROMATOGRAPHY AND GRADIENT HPLC [J].
GLOCKNER, G ;
STICKLER, M ;
WUNDERLICH, W .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 328 (1-2) :76-81
[9]   INVESTIGATION OF COPOLYMERS OF STYRENE AND ETHYL METHACRYLATE BY SIZE-EXCLUSION CHROMATOGRAPHY AND GRADIENT HPLC .2. GRADIENT HPLC USING REVERSED-PHASE CONDITIONS [J].
GLOCKNER, G ;
STICKLER, M ;
WUNDERLICH, W .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 330 (01) :46-49
[10]   GRADIENT HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF STATISTICAL AND BLOCK COPOLYMERS OF STYRENE AND TERT-BUTYL METHACRYLATE [J].
GLOCKNER, G ;
MULLER, AHE .
JOURNAL OF APPLIED POLYMER SCIENCE, 1989, 38 (09) :1761-1774