THE VIRGO PROJECT - A WIDE BAND ANTENNA FOR GRAVITATIONAL-WAVE DETECTION

被引:455
作者
BRADASCHIA, C
DELFABBRO, R
DIVIRGILIO, A
GIAZOTTO, A
KAUTZKY, H
MONTELATICI, V
PASSUELLO, D
BRILLET, A
CREGUT, O
HELLO, P
MAN, CN
MANH, PT
MARRAUD, A
SHOEMAKER, D
VINET, JY
BARONE, F
DIFIORE, L
MILANO, L
RUSSO, G
AGUIRREGABIRIA, JM
BEL, H
DURUISSEAU, JP
LEDENMAT, G
TOURRENC, P
CAPOZZI, M
LONGO, M
LOPS, M
PINTO, I
ROTOLI, G
DAMOUR, T
BONAZZOLA, S
MARCK, JA
GOURGHOULON, Y
HOLLOWAY, LE
FULIGNI, F
IAFOLLA, V
NATALE, G
机构
[1] CNRS,LAB GRAVITAT & COSMOL RELAT ORSAY,F-75005 PARIS,FRANCE
[2] NAPLES UNIV,IST NAZL FIS NUCL,DIPARTIMENTO SCI FIS,SEZ NAPOLI,I-80138 NAPLES,ITALY
[3] UNIV PARIS 06,CNRS,PARIS,FRANCE
[4] OBSERV PARIS,ASTROPHYS RELAT GRP,F-92190 MEUDON,FRANCE
[5] UNIV ILLINOIS,URBANA,IL 61801
[6] CNR FRASCATI,ROME,ITALY
[7] UNIV SALERNO,DIPARTIMENTO ELETTR,I-84100 SALERNO,ITALY
关键词
D O I
10.1016/0168-9002(90)91525-G
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The status of advancement of the VIRGO Project is presented: the first-generation results from the Pisa seismic noise super attenuator give an upper limit to the noise transfer function of 2 × 10-8 at 10 Hz. The upper limit to the absolute noise of the 400 kg test mass at 10 Hz has been measured to be 1.5 × 10-13 m/√Hz. The scheme and the related problems of the VIRGO interferometer, which is supposed to work down to 10 Hz, are also presented. At the 3rd Pisa Meeting in 1986 we presented the idea of what could be a very efficient seismic noise reduction system able to give a sensitivity h ∼ 10-25 at 10 Hz, in a 3 km interferometer for 1 year integration time. Now we have two new facts to present: the first is that the attenuation has been built, is working in Pisa, and shows remarkable characteristics. The second is the Italian-French interferometer VIRGO [1,2], a 3 km long antenna for low and high frequency (10-1000 Hz) gravitational wave (GW) detection. These two items will be presented in this article. © 1990.
引用
收藏
页码:518 / 525
页数:8
相关论文
共 14 条
  • [1] BOULANGER JL, 1988, THESIS U PARIS 6
  • [2] BRILLET A, IN PRESS OPT LETT
  • [3] 3-DIMENSIONAL SEISMIC SUPER-ATTENUATOR FOR LOW-FREQUENCY GRAVITATIONAL-WAVE DETECTION
    DELFABBRO, R
    DIVIRGILIO, A
    GIAZOTTO, A
    KAUTZKY, H
    MONTELATICI, V
    PASSUELLO, D
    [J]. PHYSICS LETTERS A, 1987, 124 (4-5) : 253 - 257
  • [4] PERFORMANCE OF A GAS SPRING HARMONIC-OSCILLATOR
    DELFABBRO, R
    DIVIRGILIO, A
    GIAZOTTO, A
    KAUTZKY, H
    MONTELATICI, V
    PASSUELLO, D
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (02) : 292 - 297
  • [5] LOW-FREQUENCY BEHAVIOR OF THE PISA SEISMIC NOISE SUPER-ATTENUATOR FOR GRAVITATIONAL-WAVE DETECTION
    DELFABBRO, R
    DIVIRGILIO, A
    GIAZOTTO, A
    KAUTZKY, H
    MONTELATICI, V
    PASSUELLO, D
    [J]. PHYSICS LETTERS A, 1988, 133 (09) : 471 - 475
  • [6] 1ST RESULTS FROM THE PISA SEISMIC NOISE SUPER-ATTENUATOR FOR LOW-FREQUENCY GRAVITATIONAL-WAVE DETECTION
    DELFABBRO, R
    DIVIRGILIO, A
    GIAZOTTO, A
    KAUTZKY, H
    MONTELATICI, V
    PASSUELLO, D
    [J]. PHYSICS LETTERS A, 1988, 132 (05) : 237 - 240
  • [7] DELFABBRO R, IN PRESS LOW NOISE D
  • [8] DELFABBRO R, 1989, PHYS LETT A, V132, P329
  • [9] ELECTRONIC COOLING OF RESONANT GRAVITY GRADIOMETERS
    FORWARD, RL
    [J]. JOURNAL OF APPLIED PHYSICS, 1979, 50 (01) : 1 - 6
  • [10] GIAZOTTO A, 1986, 7 C REL GEN FIS GRAV