POWER-CONSUMPTION FOR A SCRAPED-SURFACE HEAT-EXCHANGER WITH A NO-LEAK REACTOR

被引:3
作者
ALTIOKKA, MR
机构
[1] Chemical Engineering Department, Faculty of Engineering and Architecture, Anadolu University, Eskiqehir
关键词
D O I
10.1021/ie00010a018
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this work, the power consumption for a scraped-surface heat exchanger with a "no-leak" reactor was investigated to scale up a pilot plant reactor for industrial use. The experimental results Obtained at various speeds of rotation and fluid viscosities were analyzed by nonlinear regression computation using the Nelder algorithm. Using the results of this analysis, the power consumption expression given for a "with-leak" reactor in a previous work was modified to give that of the reactor with "no leak". That is, P(L) = [251D(o)1.79n(B)0.68L(B)/(D(o) - D(i))0.31]N1.93mu0.61.
引用
收藏
页码:2385 / 2388
页数:4
相关论文
共 11 条