WINDOW SELECTION FOR DUAL PHOTOPEAK WINDOW SCATTER CORRECTION IN TC-99M IMAGING

被引:10
作者
DEVRIES, DJ [1 ]
KING, MA [1 ]
机构
[1] WORCESTER POLYTECH INST,WORCESTER,MA
关键词
D O I
10.1109/23.340646
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The width and placement of the windows for the dual photopeak window (DPW) scatter subtraction method for Tc-99m imaging is investigated in order to obtain a method that is stable on a multihead detector system for single photon emission computed tomography (SPECT) and is capable of providing a good scatter estimate for extended objects. For various window pairs, stability and noise were examined with experiments using a SPECT system, while Monte Carlo simulations were used to predict the accuracy of scatter estimates for a variety of objects and to guide the development of regression relations for various window pairs. The DPW method that resulted from this study was implemented with a symmetric 20% photopeak window composed of a 15% asymmetric photopeak window and a 5% lower window abutted at 7 keV below the peak A power function regression was used to relate the scatter-to-total ratio to the lower window-to-total ratio at each pixel, from which an estimated scatter image was calculated. DPW demonstrated good stability, achieved by abutting the two windows away from the peak Performance was assessed and compared with Compton window subtraction (CWS). For simulated extended objects, DPW generally produced a less biased scatter estimate than the commonly used CWS method with k = 0.5. In aquisitions of a clinical SPECT phantom, contrast recovery was comparable for both DPW and CWS; however, DPW showed greater visual contrast in clinical SPECT bone studies.
引用
收藏
页码:2771 / 2778
页数:8
相关论文
共 17 条
  • [1] DEVRIES DJ, 1993, J NUCL MED, V34, P72
  • [2] MONTE-CARLO EVALUATION OF COMPTON SCATTER SUBTRACTION IN SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY
    FLOYD, CE
    JASZCZAK, RJ
    HARRIS, CC
    GREER, KL
    COLEMAN, RE
    [J]. MEDICAL PHYSICS, 1985, 12 (06) : 776 - 778
  • [3] GILARDI MC, 1988, J NUCL MED, V29, P1971
  • [4] A SCATTER CORRECTION METHOD FOR TL-201 IMAGES - A MONTE-CARLO INVESTIGATION
    HADEMENOS, GJ
    KING, MA
    LJUNGBERG, M
    ZUBAL, IG
    HARRELL, CR
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 1179 - 1186
  • [5] SCATTER COMPENSATION TECHNIQUES FOR SPECT
    JASZCZAK, RJ
    FLOYD, CE
    COLEMAN, RE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (01) : 786 - 793
  • [6] JASZCZAK RJ, 1984, J NUCL MED, V25, P893
  • [7] KING MA, 1985, EUR J NUCL MED, V10, P458, DOI 10.1007/BF00256591
  • [8] KING MA, 1992, J NUCL MED, V33, P605
  • [9] KING MA, 1992, 1992 IEEE NUCL SCI S, V2, P1179
  • [10] KORAL KF, 1990, J NUCL MED, V31, P90