POTENTIOMETRIC DETERMINATION OF CHLORIDES WITH AN AIR-GAP CYANIDE SENSOR

被引:5
作者
BARANOWSKI, R
KUBIK, T
机构
[1] Department of Analytical and General Chemistry, Silesian Technical University
关键词
D O I
10.1016/0039-9140(93)80227-I
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new electroanalytical method for determining chloride ions with an Air-Gap cyanide sensor system is described. The method is based on the reaction of chloride with mercury(II) cyanide in dilute sulphuric acid. This reaction leads to hydrogen cyanide which can be determined with an Air-Gap cyanide sensor. Optimum concentrations of mercury(II) cyanide and sulphuric acid were established and an analytical curve was prepared for 1 x 10(-1)-1 x 10(-5)M Cl-. The slope of the calibration curve was equal to 62.8 mV/log C. The correlation coefficient (R) was equal to 0.9992. The method can determine chloride with good results in high saline solutions and in the presence of surfactants, which is in contrast to direct potentiometry with a chloride electrode. The method was applied for chloride determination in fuses used for initiating explosions. The chlorides were determined both in the raw materials used to prepare the fuse braids and in the other fuse components. Chloride was also determined in drinking water and river water. In dependence of source, chloride amount analyzed in drinking water was in the range 2.18-182.6 mg/l. and 25.8 mg/l. in river water. A comparative analysis was carried out. In the first case, chloride was determined by a turbidimetric method, whereas in the second one by potentiometric titration against a chloride-ISE.
引用
收藏
页码:1465 / 1471
页数:7
相关论文
共 14 条
[1]  
BATHY MK, 1971, TALANTA, V8, P799
[2]  
CIBA J, 1989, PORADNIK CHEM ANALIT, V1, P123
[3]   EFFECT OF ANIONIC SURFACTANTS ON CALCIUM ION-SELECTIVE ELECTRODES [J].
CRAGGS, A ;
MOODY, GJ ;
THOMAS, JDR ;
BIRCH, BJ .
ANALYST, 1980, 105 (1250) :426-431
[4]   INDIRECT DETERMINATION OF MERCURY(II) WITH AN AIR-GAP CYANIDE SENSOR [J].
CZICHON, P ;
FLIGIER, J ;
GREGOROWICZ, Z .
ANALYTICA CHIMICA ACTA, 1981, 126 (MAY) :221-224
[5]  
FEIGL F, 1967, MIKROCHIM ACTA, V2, P339
[6]   A VERY SIMPLE AIR-GAP CYANIDE SENSOR [J].
FLIGIER, J ;
CZICHON, P ;
GREGOROWICZ, Z .
ANALYTICA CHIMICA ACTA, 1980, 118 (01) :145-148
[7]   STUDIES OF CALCIUM ION-SELECTIVE ELECTRODES IN THE PRESENCE OF ANIONIC SURFACTANTS [J].
FREND, AJ ;
MOODY, GJ ;
THOMAS, JDR ;
BIRCH, BJ .
ANALYST, 1983, 108 (1290) :1072-1081
[8]   EFFECT OF SURFACTANTS ON THE DETERMINATION OF NITRATE IN STREAM WATERS BY USING A NITRATE ION-SELECTIVE ELECTRODE [J].
HARA, H ;
OKAZAKI, S .
ANALYST, 1985, 110 (01) :11-14
[9]  
HERMANOWICZ W, 1976, FIZYCZNO CHEM BADANI, P504
[10]   EFFECT OF SURFACTANTS ON THE RESPONSE OF ION-SELECTIVE ELECTRODES WITH POLYVINYL-CHLORIDE) MEMBRANES [J].
HULANICKI, A ;
TROJANOWICZ, M ;
POBOZY, E .
ANALYST, 1982, 107 (1280) :1356-1362