PENICILLINASE OPTODES - SUBSTRATE DETERMINATIONS USING BATCH, CONTINUOUS-FLOW AND FLOW-INJECTION ANALYSIS OPERATION CONDITIONS

被引:13
作者
HOBEL, W [1 ]
PAPPERGER, A [1 ]
POLSTER, J [1 ]
机构
[1] TECH UNIV MUNICH,LEHRSTUHL ALLGEMEINE CHEM & BIOCHEM,W-8050 FREISING,GERMANY
关键词
OPTODES; FLOW INJECTION ANALYSIS; CONTINUOUS FLOW; BATCH MODE; PENICILLINASE; PENICILLIN-G; POLYACRYLAMIDE; GELATIN; FITC-DEXTRAN;
D O I
10.1016/0956-5663(92)85006-V
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Determination of penicillin G is shown with two different sensor types and with three different working conditions for each sensor. A universal sensor head has been constructed for this purpose, which allows use in either batch, continuous-flow or flow injection analysis (FIA) mode. In addition, two different immobilization techniques are compared. While the simple entrapment of penicillinase and fluorescein (coupled as isothiocyanate to dextran) in polyacrylamide gel shows good stability with time, the cross-linked gelatin-penicillinase-FLUOS optode loses its activity after one week. On the other hand, the sensitivity and concentration range for determination of penicillin G are similar for both polyacrylamide and gelatin optodes. Both optodes have comparable response times of about 60 s (or 10 s using low 'integration time' for signal processing). Comparing all three different working conditions, there is a decrease in sensitivity in the order continuous flow > batch > FIA.
引用
收藏
页码:549 / 557
页数:9
相关论文
共 22 条
  • [1] BRAND U, 1989, GBF MONOG SERIES, V13, P127
  • [2] BIO-FIELD-EFFECT TRANSISTORS AS DETECTORS IN FLOW-INJECTION ANALYSIS
    BRAND, U
    REINHARDT, B
    RUTHER, F
    SCHEPER, T
    SCHUGERL, K
    [J]. ANALYTICA CHIMICA ACTA, 1990, 238 (01) : 201 - 210
  • [3] BUSCH M, 1990, DECHEMA BIOTECHNOL B, V4, P953
  • [4] PH-BASED ENZYME POTENTIOMETRIC SENSORS .1. THEORY
    CARAS, SD
    JANATA, J
    SAUPE, D
    SCHMITT, K
    [J]. ANALYTICAL CHEMISTRY, 1985, 57 (09) : 1917 - 1920
  • [5] IMPROVED PENICILLIN SELECTIVE ENZYME ELECTRODE
    CULLEN, LF
    RUSLING, JF
    SCHLEIFER, A
    PAPARIELLO, GJ
    [J]. ANALYTICAL CHEMISTRY, 1974, 46 (13) : 1955 - 1961
  • [6] ENZYME ELECTRODES FOR LACTATE AND MALTOSE USING A FLUORIDE ION-SENSITIVE ELECTRODE
    DRANSFELD, I
    HINTSCHE, R
    SCHELLER, F
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 333 (01): : 23 - 25
  • [7] MICROBIAL SENSOR FOR PENICILLINS USING A RECOMBINANT STRAIN OF ESCHERICHIA-COLI
    GALINDO, E
    BAUTISTA, D
    GARCIA, JL
    QUINTERO, R
    [J]. ENZYME AND MICROBIAL TECHNOLOGY, 1990, 12 (09) : 642 - 646
  • [8] FLOW-INJECTION DETERMINATION OF PENICILLINS USING IMMOBILIZED PENICILLINASE IN A SINGLE BEAD STRING REACTOR
    GNANASEKARAN, R
    MOTTOLA, HA
    [J]. ANALYTICAL CHEMISTRY, 1985, 57 (06) : 1005 - 1009
  • [9] SOLID-PHASE OPTOELECTRONIC SENSORS FOR BIOCHEMICAL-ANALYSIS
    GOLDFINCH, MJ
    LOWE, CR
    [J]. ANALYTICAL BIOCHEMISTRY, 1984, 138 (02) : 430 - 436
  • [10] HOBEL W, 1991, P SENSOR 91, V4, P99