APPLICATIONS OF ADAPTIVE FILTERING TO ECG ANALYSIS - NOISE CANCELLATION AND ARRHYTHMIA DETECTION

被引:562
作者
THAKOR, NV
ZHU, YS
机构
[1] Department of Biomedical Engineering, The Johns Hopkins School of Medicine, Baltimore
[2] Department of Biomedical Engineering, The Johns Hopkins School of Medicine, Baltimore
[3] Department of Electrical Engineering, University of Science and Technology of China, (USTC), Beijing
关键词
D O I
10.1109/10.83591
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Several adaptive filter structures are proposed for noise cancellation and arrhythmia detection. The adaptive filter essentially minimizes the mean-squared error between a primary input, which is the noisy ECG, and a reference input, which is either noise that is correlated in some way with the noise in the primary input or a signal that is correlated only with ECG in the primary input. Different filter structures are presented to eliminate the diverse forms of noise: baseline wander, 60 Hz power line interference, muscle noise, and motion artifact. An adaptive recurrent filler structure is proposed for acquiring the impulse response of the normal QRS complex. The primary input of the filter is the ECG signal to be analyzed, while the reference input is an impulse train coincident with the QRS complexes. This method is applied to several arrhythmia detection problems: detection of P-waves, premature ventricular complexes, and recognition of conduction block, atrial fibrillation, and paced rhythm.
引用
收藏
页码:785 / 794
页数:10
相关论文
共 23 条
[1]   DIGITAL-FILTERS FOR REAL-TIME ECG SIGNAL-PROCESSING USING MICROPROCESSORS [J].
AHLSTROM, ML ;
TOMPKINS, WJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (09) :708-713
[2]   ECG WAVE-FORM ANALYSIS BY SIGNIFICANT POINT EXTRACTION .2. PATTERN-MATCHING [J].
CHENG, QL ;
LEE, HS ;
THAKOR, NV .
COMPUTERS AND BIOMEDICAL RESEARCH, 1987, 20 (05) :428-442
[3]  
DuFault R. A., 1986, Proceedings of the Eighth Annual Conference of the IEEE/Engineering in Medicine and Biology Society (Cat. No. 86CH2368-9), P325
[4]   FETAL ELECTROCARDIOGRAM ENHANCEMENT BY TIME-SEQUENCED ADAPTIVE FILTERING [J].
FERRARA, ER ;
WIDROW, B .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1982, 29 (06) :458-460
[5]   A LEARNING FILTER FOR REMOVING NOISE INTERFERENCE [J].
FURNO, GS ;
TOMPKINS, WJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1983, 30 (04) :234-235
[6]  
Huhta J. C., 1974, BIOMEDICAL ELECTRODE, P129
[7]   60-HZ INTERFERENCE IN ELECTROCARDIOGRAPHY [J].
HUHTA, JC ;
WEBSTER, JG .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1973, BM20 (02) :91-101
[8]   RECURSIVE DIGITAL FILTERS FOR BIOLOGICAL SIGNALS [J].
LYNN, PA .
MEDICAL & BIOLOGICAL ENGINEERING, 1971, 9 (01) :37-&
[10]   SOFTWARE QRS DETECTION IN AMBULATORY MONITORING - A REVIEW [J].
PAHLM, O ;
SORNMO, L .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1984, 22 (04) :289-297