HYDROXYAPATITE COATING MODIFIES IMPLANT MEMBRANE FORMATION - CONTROLLED MICROMOTION STUDIED IN DOGS

被引:174
作者
SOBALLE, K
BROCKSTEDTRASMUSSEN, H
HANSEN, ES
BUNGER, C
机构
[1] AARHUS KOMMUNE HOSP, INST PATHOL, DK-8000 AARHUS, DENMARK
[2] AARHUS KOMMUNE HOSP, INST EXPTL CLIN RES, DK-8000 AARHUS, DENMARK
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1992年 / 63卷 / 02期
关键词
D O I
10.3109/17453679209154808
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We studied the influence of controlled micromovements between bone and porous titanium alloy implants with and without hydroxyapatite coating. A dynamically loaded unstable device producing approximately 150-mu-m axial translation of knee implants during each gait cycle was developed. Stable implants served as controls. Matched stable and unstable implants with either porous titanium (Ti) or hydroxyapatite (HA) coating surrounded by a gap of 0.75 mm were inserted into the weight-bearing regions of the medial femoral condyles in 14 mature dogs. Histologic analysis after 4 weeks showed a fibrous membrane surrounding both types of implants subjected to micromovements, whereas various amounts of bone ingrowth was obtained in the stable implants. The membrane around unstable HA implants was thinner than that around unstable Ti implants. Islands of fibrocartilaginous tissue characterized the membrane around unstable HA implants, whereas fibrous connective tissue surrounded unstable Ti implants. The collagen concentration of the fibrous membranes was higher around unstable HA implants compared with Ti implants. Instability reduced the shear strength of the implants. However, the shear strength of unstable HA implants exceeded that of the Ti implants, both unstable and stable. The greatest shear strength was obtained by stable HA implants, i.e., tenfold greater than that of stable Ti implants. The gap-healing capacity around stable HA implants increased toward the HA surface, and was greater than that around Ti implants. Our study demonstrates that micromovements between bone and implant inhibit bone ingrowth and lead to the development of a fibrous membrane. The superior fixation of unstable HA implants compared with unstable Ti implants may be ascribed to the presence of fibrocartilage, a higher collagen concentration, and radiating orientation of collagen fibers in the membrane. The strongest mechanical anchorage and the greatest amount of bone ingrowth was obtained by stable implants coated with hydroxyapatite.
引用
收藏
页码:128 / 140
页数:13
相关论文
共 36 条
[1]  
ADRIAN MJ, 1966, AM J VET RES, V27, P90
[2]   METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[3]  
BEIGHT J, 1989, 35TH T ANN M ORTH RE, V14, P334
[4]  
Bloom W., 1975, TXB HISTOLOGY
[5]  
Branson P J, 1989, J Arthroplasty, V4, P21, DOI 10.1016/S0883-5403(89)80049-X
[6]   INTRAMEDULLARY BONE REPAIR AND INGROWTH INTO POROUS COATED IMPLANTS IN THE ADULT CHICKEN - A HISTOLOGIC-STUDY AND BIOCHEMICAL-ANALYSIS OF COLLAGENS [J].
BROWN, CC ;
MCLAUGHLIN, RE ;
BALIAN, G .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (03) :316-325
[7]   MICROMOTION OF CEMENTED AND UNCEMENTED FEMORAL COMPONENTS [J].
BURKE, DW ;
OCONNOR, DO ;
ZALENSKI, EB ;
JASTY, M ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (01) :33-37
[8]   THE EFFECT OF PLASMA-SPRAYED CALCIUM-PHOSPHATE CERAMIC COATINGS ON THE METAL-ION RELEASE FROM POROUS TITANIUM AND COBALT-CHROMIUM ALLOYS [J].
DUCHEYNE, P ;
HEALY, KE .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (12) :1137-1163
[9]  
GEESINK RGT, 1987, CLIN ORTHOP RELAT R, P147
[10]   A METHOD FOR PREPARING AND STAINING HISTOLOGICAL SECTIONS CONTAINING TITANIUM IMPLANTS FOR LIGHT-MICROSCOPY [J].
GOTFREDSEN, K ;
BUDTZJORGENSEN, E ;
JENSEN, LN .
STAIN TECHNOLOGY, 1989, 64 (03) :121-127