GLUCOSE BIOSENSOR USING GLUCOSE-OXIDASE IMMOBILIZED IN POLYANILINE

被引:52
作者
PARENTE, AH [1 ]
MARQUES, ETA [1 ]
AZEVEDO, WM [1 ]
DINIZ, FB [1 ]
MELO, EHM [1 ]
FILHO, JLL [1 ]
机构
[1] UNIV FED PERNAMBUCO,DEPT QUIM FUNDAMENTAL,BR-50730 RECIFE,PE,BRAZIL
关键词
GLUCOSE OXIDASE; POLYANILINE; BIOSENSOR; OXYGEN ELECTRODE;
D O I
10.1007/BF02788878
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A biosensor for glucose utilizing kinetics of glucose oxidase (EC 1.1.3.4.) was developed. The enzyme was immobilized on polyaniline by covalent bonding, using glutaraldehyde as a bifunctional agent. The system showed a linear response up to 2.2 mM of glucose with a response time of 2.5-4.0 min. In addition, the immobilized enzyme had a higher activity between pH 6.5 and 7.5. The system retained 50% of its activity after 30 d of daily use. The optical absorption spectra of the polyaniline/glucose oxidase electrode after glucose had been added to the buffer solution showed that the absorption band around 800 nm had changed considerably when glucose was allowed to react with the electrode. This optical variation makes polyaniline a very promising polymer for use as a support in optical sensor for clinical application.
引用
收藏
页码:267 / 273
页数:7
相关论文
共 14 条
[1]   DIRECT ELECTROCHEMICAL DETERMINATION OF GLUCOSE-OXIDASE IN BIOLOGICAL SAMPLES [J].
AUBREELECAT, A ;
HERVAGAULT, C ;
DELACOUR, A ;
BEAUDE, P ;
BOURDILLON, C ;
REMY, MH .
ANALYTICAL BIOCHEMISTRY, 1989, 178 (02) :427-430
[2]   GLUCONIC ACID PRODUCTION BY AN IMMOBILIZED GLUCOSE-OXIDASE REACTOR WITH ELECTROCHEMICAL REGENERATION OF AN ARTIFICIAL ELECTRON-ACCEPTOR [J].
BOURDILLON, C ;
LORTIE, R ;
LAVAL, JM .
BIOTECHNOLOGY AND BIOENGINEERING, 1988, 31 (06) :553-558
[3]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[4]   INSULATOR-TO-METAL TRANSITION IN POLYANILINE [J].
EPSTEIN, AJ ;
GINDER, JM ;
ZUO, F ;
BIGELOW, RW ;
WOO, HS ;
TANNER, DB ;
RICHTER, AF ;
HUANG, WS ;
MACDIARMID, AG .
SYNTHETIC METALS, 1987, 18 (1-3) :303-309
[5]  
GENIES EM, 1987, J ELECTROANAL CHEM, V67, P220
[6]   CHARACTERIZATION OF PERFLUOROSULFONIC ACID POLYMER COATED ENZYME ELECTRODES AND A MINIATURIZED INTEGRATED POTENTIOSTAT FOR GLUCOSE ANALYSIS IN WHOLE-BLOOD [J].
HARRISON, DJ ;
TURNER, RFB ;
BALTES, HP .
ANALYTICAL CHEMISTRY, 1988, 60 (19) :2002-2007
[7]   ELECTROCATALYSIS WITH A GLUCOSE OXIDASE-IMMOBILIZED GRAPHITE ELECTRODE [J].
IKEDA, T ;
KATASHO, I ;
KAMEI, M ;
SENDA, M .
AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1984, 48 (08) :1969-1976
[8]  
KADDISH AH, 1964, AM J MED ELECTRON, V3, P82
[9]   EFFECT OF HYDROGEN PEROXIDE ON GLUCOSE OXIDASE FROM ASPERGILLUS NIGER [J].
KLEPPE, K .
BIOCHEMISTRY, 1966, 5 (01) :139-&
[10]   A LOW-COST OXYGEN METER [J].
MARQUES, ETH ;
NETTO, FACS ;
FILHO, JLL .
BIOCHEMICAL EDUCATION, 1991, 19 (02) :77-78