DETERMINATION OF MIZOLASTINE, A NEW ANTIHISTAMINIC DRUG, IN HUMAN PLASMA BY LIQUID-LIQUID-EXTRACTION, SOLID-PHASE EXTRACTION AND COLUMN-SWITCHING TECHNIQUES IN COMBINATION WITH HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:22
作者
ASCALONE, V [1 ]
GUINEBAULT, P [1 ]
ROUCHOUSE, A [1 ]
机构
[1] LERS SYNTHELABO,DEPT CLIN RES,SYNTHELABO RECH,F-91380 CHILLY MAZARIN,FRANCE
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1993年 / 619卷 / 02期
关键词
D O I
10.1016/0378-4347(93)80117-M
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the determination of mizolastine (2-[[[1-[(4-fluorophenyl)methyl]-1H-benzimidazol-2-yl]-4-piperidinyl]methylamino]-4(3H)-pyrimidinone, SL 85.0324), a new antihistaminic drug, in human plasma, three methods were developed based on liquid-liquid extraction, solid-phase extraction and column-switching in combination with high-performance liquid chromatography with ultraviolet detection. The liquid-liquid extraction method included a back-extraction step that preconcentrates the drug into a small aqueous volume, resulting in very high sensitivity (0.5 ng/ml of plasma); it can be used in conventional bioanalytical laboratories that do not have sophisticated automatic devices. The solid-phase extraction method is performed by using a robotic system (Benchmate). It is completely automated from the initial sampling to the final injection into the chromatograph. It has a good sensitivity (1 ng/ml of plasma), but requires an expensive apparatus and skilled analysts. The column-switching method is based on a solid-phase extraction performed on-line with chromatographic analysis; it is not completely automatic, because some operations are performed manually. The device required for valve switching is not expensive and can be managed by a simple integrator or a personal computer; it is very easy to use and affords a sensitivity (2.5 ng/ml of plasma) that generally satisfies the needs of pharmacokinetic investigations of mizolastine. The conditions were similar for all the three methods: a C-8 type column, an eluent of phosphate buffer and acetonitrile, and a spectrophotometric ultraviolet detector operated at 285 nm.
引用
收藏
页码:275 / 284
页数:10
相关论文
共 13 条
[1]   SIMPLIFIED PROCEDURES FOR THE DETERMINATION OF FENOLDOPAM AND ITS METABOLITES IN HUMAN-PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION - COMPARISON OF MANUAL AND ROBOTIC SAMPLE PREPARATION METHODS [J].
BOPPANA, VK ;
DOLCE, KM ;
CYRONAK, MJ ;
ZIEMNIAK, JA .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 487 (02) :385-399
[2]  
CHOW FK, 1991, HPLC PHARM IND, P41
[3]  
Cortes H. J., 1990, MULTIDIMENSIONAL CHR, P219
[4]  
DALE A, 1991, EUR CHROMATOGR ANAL, V3, P5
[5]  
DESILVA JAF, 1980, TRACE ORGANIC SAMPLE, P192
[6]  
FELDER RA, 1991, HPLC PHARM IND, P185
[7]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF NEFAZODONE AND ITS METABOLITES IN HUMAN PLASMA USING LABORATORY ROBOTICS [J].
FRANC, JE ;
DUNCAN, GF ;
FARMEN, RH ;
PITTMAN, KA .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 570 (01) :129-138
[8]   AUTOMATED ROBOTIC EXTRACTION AND SUBSEQUENT ANALYSIS OF DICLOFENAC IN PLASMA SAMPLES [J].
GRANDJEAN, D ;
BEOLOR, JC ;
QUINCON, MT ;
SAVEL, E .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1989, 78 (03) :247-249
[9]  
KOENIGBAUER MJ, 1990, LC GC EUR, V3, P10
[10]  
SCHILL G, 1978, SEPARATION METHODS D, P182