IMAGE QUALITY IN DYNAMIC CT - A CLINICAL DISCUSSION

被引:8
作者
FOLEY, WD
机构
[1] Department of Radiology, Medical College of Wisconsin, Milwaukee
关键词
ANEURYSM; AORTIC; COMPUTED TOMOGRAPHY (CT); CONTRAST ENHANCEMENT; IMAGE QUALITY; TECHNOLOGY; LIVER; CT;
D O I
10.1148/radiographics.13.1.8426933
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Modern state-of-the-art computed tomographic (CT) scanners emphasize three capabilities: image quality, dynamic scan capability, and a high-resolution thin-section technique. Image quality is fundamental and dependent on optimum performance and the interrelationship of all system components. Variables that affect the performance of the scanner include x-ray tube output and rate of heat dissipation; quantum detection efficiency; electronic noise in the acquisition system; speed, accuracy, and integration of mechanical motion in the gantry and table; and the algorithm used for image reconstruction. System design must allow for dynamic scan operation, either in the single-scan or cluster mode, with short interscan or intergroup delays or, as more recently developed, with helical acquisition. Dynamic scanning is frequently used for nonneurologic applications, including diagnosis of vascular and perivascular diseases and multifocal organ disease, particularly hepatic disease. Efficient operation depends on rapid reconstruction and display capability. Modern systems have been engineered to provide flexible modes of operation, particularly in dynamic scanning, and rapid on-line review and analysis, all of which serve to improve the quality of images produced with dynamic CT scanning.
引用
收藏
页码:225 / 233
页数:9
相关论文
共 15 条
  • [1] CT EVALUATION OF ESOPHAGEAL AND UPPER ABDOMINAL VARICES
    CLARK, KE
    FOLEY, WD
    LAWSON, TL
    BERLAND, LL
    MADDISON, FE
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (04) : 510 - 515
  • [2] BOLUS GEOMETRY AND DYNAMICS AFTER INTRAVENOUS CONTRAST-MEDIUM INJECTION
    CLAUSSEN, CD
    BANZER, D
    PFRETZSCHNER, C
    KALENDER, WA
    SCHORNER, W
    [J]. RADIOLOGY, 1984, 153 (02) : 365 - 368
  • [3] PULMONARY NODULE - EVALUATION WITH SPIRAL VOLUMETRIC CT
    COSTELLO, P
    ANDERSON, W
    BLUME, D
    [J]. RADIOLOGY, 1991, 179 (03) : 875 - 876
  • [4] COSTELLO P, 1991, RADIOLOGY, V181, P274
  • [5] RIGHT WINDOW FOR DYNAMIC HEPATIC CT
    COX, IH
    FOLEY, WD
    HOFFMANN, RG
    [J]. RADIOLOGY, 1991, 181 (01) : 18 - 21
  • [6] CONTRAST ENHANCEMENT TECHNIQUE FOR DYNAMIC HEPATIC COMPUTED TOMOGRAPHIC SCANNING
    FOLEY, WD
    BERLAND, LL
    LAWSON, TL
    SMITH, DF
    THORSEN, MK
    [J]. RADIOLOGY, 1983, 147 (03) : 797 - 803
  • [7] DYNAMIC HEPATIC CT
    FOLEY, WD
    [J]. RADIOLOGY, 1989, 170 (03) : 617 - 622
  • [8] PANCREATIC DUCTAL ADENOCARCINOMA - DIAGNOSIS AND STAGING WITH DYNAMIC CT
    FREENY, PC
    MARKS, WM
    RYAN, JA
    TRAVERSO, LW
    [J]. RADIOLOGY, 1988, 166 (01) : 125 - 133
  • [9] Hanson K M, 1981, RADIOLOGY SKULL BRAI, P3941
  • [10] CT CHARACTERISTICS OF AORTIC ATHEROSCLEROTIC ANEURYSM VERSUS AORTIC DISSECTION
    HEIBERG, E
    WOLVERSON, MK
    SUNDARAM, M
    SHIELDS, JB
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (01) : 78 - 83