MINIMUM SCAN SPEEDS FOR SUPPRESSION OF MOTION ARTIFACTS IN CT

被引:161
作者
RITCHIE, CJ
GODWIN, JD
CRAWFORD, CR
STANFORD, W
ANNO, H
KIM, Y
机构
[1] UNIV WASHINGTON, DEPT RADIOL, 1959 NE PACIFIC ST, SEATTLE, WA 98195 USA
[2] UNIV WASHINGTON, DEPT BIOENGN, SEATTLE, WA 98195 USA
[3] UNIV WASHINGTON, DEPT ELECT ENGN, SEATTLE, WA 98195 USA
[4] GE, MED SYST, MILWAUKEE, WI 53201 USA
[5] UNIV IOWA, DEPT RADIOL, IOWA CITY, IA 52242 USA
[6] FUJITA HLTH UNIV, DEPT RADIOL, TOYOAKE, JAPAN
关键词
COMPUTED TOMOGRAPHY (CT); ARTIFACT; PHYSICS; HEART; CT; LUNG;
D O I
10.1148/radiology.185.1.1523332
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cardiac and ventilatory motions cause artifacts at chest computed tomography (CT). To determine how short the scan times on third-generation units must be to avoid such artifacts, motion was measured with fast and ultrafast CT scans. Minimum detectable motion was then determined. The longest scan time that avoided a barely perceptible artifact was calculated by dividing the minimum detectable motion by the peak physiologic velocity. The posterior left ventricular wall moved at a maximum velocity of 52.5 mm/sec, necessitating a scan time of 19.1 msec or less to avoid artifact. Lung vessels near the heart moved at 40.5 mm/sec for a scan time of 24.7 msec or less. During quiet breathing, pulmonary vessels moved at 10.7 mm/sec for a scan time of 93.5 msec or less. The authors conclude that the shortest scan time on third-generation units (0.6 second) cannot prevent all artifacts arising from motion in the chest. Even ultrafast scan times (50 msec) are not short enough to eliminate artifacts on these units. Thus, reduction of motion artifacts will require techniques other than fast scanning.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 27 条
[1]   EFFECTS OF BIOLOGICAL MOTION ON CT RESOLUTION [J].
ALFIDI, RJ ;
MACINTYRE, WJ ;
HAAGA, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1976, 127 (01) :11-15
[2]   A NOTE ON THE GENERATION OF RANDOM NORMAL DEVIATES [J].
BOX, GEP ;
MULLER, ME .
ANNALS OF MATHEMATICAL STATISTICS, 1958, 29 (02) :610-611
[3]   CARDIAC COMPUTED-TOMOGRAPHY [J].
BOYD, DP ;
LIPTON, MJ .
PROCEEDINGS OF THE IEEE, 1983, 71 (03) :298-307
[4]   REDUCTION OF MOTION ARTIFACTS IN COMPUTED-TOMOGRAPHY [J].
CRAWFORD, CR ;
GODWIN, JD ;
PELC, NJ .
IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 :485-486
[5]  
CRAWFORD CR, 1990, RADIOLOGY, V177, P277
[6]  
CRAWFORD CR, 1991, Patent No. 4994965
[7]  
CRAWFORD CR, 1987, P IEEE ENG MED BIOL, V9, P1670
[8]   EVALUATION OF ULTRAFAST CT SCANNING OF THE ADULT ABDOMEN [J].
GOLDBERG, HI ;
GOULD, RG ;
FEUERSTEIN, IM ;
SIGETI, JS ;
LIPTON, MJ .
INVESTIGATIVE RADIOLOGY, 1989, 24 (07) :537-543
[9]   ARTIFACTS ON LUNG CT SCANS - REMOVAL WITH FOURIER FILTRATION [J].
HELENON, O ;
CHANIN, DS ;
LAVALJEANTET, M ;
FRIJA, J .
RADIOLOGY, 1989, 171 (02) :572-574
[10]   ULTRASONIC DETERMINATION OF LEFT VENTRICULAR WALL MOTION IN NORMAL MAN . STUDIES AT REST AND AFTER EXERCISE [J].
KRAUNZ, RF ;
KENNEDY, JW .
AMERICAN HEART JOURNAL, 1970, 79 (01) :36-+