AN AUTOMATIC MICROCOMPUTER SYSTEM FOR ANALYSIS OF MONOPHASIC ACTION-POTENTIALS

被引:13
作者
KANAAN, N
JENKINS, J
KADISH, A
机构
[1] UNIV MICHIGAN HOSP,CARDIOL,ANN ARBOR,MI 48109
[2] UNIV MICHIGAN,DEPT ELECT ENGN,BIOENGN PROGRAM,ANN ARBOR,MI 48109
[3] UNIV MICHIGAN,DEPT INTERNAL MED,ANN ARBOR,MI 48109
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1990年 / 13卷 / 02期
关键词
action potential duration; automatic interval measurement; contact electrode; monophasic action potential; pacing;
D O I
10.1111/j.1540-8159.1990.tb05070.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A computer system for rapid measurement and analysis of monophasic action potentials (MAPs) recorded in vivo was developed. MAPs recorded from the epicardium of mongrel dogs using a contact electrode were digitized by analog‐to‐digital conversion at a sampling rate of 1 kHz per channel for computer data acquisition. Activation time was detected using a sliding 10‐point window at the location where the average positive dV/dT exceeds an adjustable threshold value in order to eliminate spurious detection due to baseline variability or motion artifact. Action potential duration fAPDJ was determined at 50% and 90% (APD50, APD90) repolarization levels at the first sample point below these defection levels. In addition, a tangent algorithm (APD,tan) that detects peak negative dV/dT during repolarization was developed. APDtan was determined from the location of onset of activation to the intersection of the tangent and baseline. APDtan allowed estimation of APD in the presence of subsequent premature beats when APD80 was not measurable. To validate activation time measurements, 4,600 action potentials were analyzed during fixed rate pacing. Over a range of paced coupling intervals from 200 to 1000 msec, an R2 value of 0.99968 and a slope of 0.9959 were obtained by linear regression between paced and calculated intervals. To validate APD measurements, 5035 action potentials were analyzed in five animals during fixed rate pacing (longer than 3 minutes) when action potential duration should be constant. Average coefficients of variation of 1.25%, 1.65%, and 1.14% were obtained for APD50, APD90, and APDtan, respectively. This algorithm provides a rapid and accurate method to analyze MAP activation and duration for basic physiological studies such as the determination of initiation of arrhythmias. Copyright © 1990, Wiley Blackwell. All rights reserved
引用
收藏
页码:196 / 206
页数:11
相关论文
共 31 条
[1]   MAGNESIUM SUPPRESSION OF EARLY AFTERDEPOLARIZATIONS AND VENTRICULAR TACHYARRHYTHMIAS INDUCED BY CESIUM IN DOGS [J].
BAILIE, DS ;
INOUE, H ;
KASEDA, S ;
BENDAVID, J ;
ZIPES, DP .
CIRCULATION, 1988, 77 (06) :1395-1402
[2]   DIFFERENTIAL RESPONSE TO RIGHT AND LEFT ANSAE SUBCLAVIAE STIMULATION OF EARLY AFTERDEPOLARIZATIONS AND VENTRICULAR-TACHYCARDIA INDUCED BY CESIUM IN DOGS [J].
BENDAVID, J ;
ZIPES, DP .
CIRCULATION, 1988, 78 (05) :1241-1250
[3]   STUDY OF THE FACTORS RESPONSIBLE FOR RATE-DEPENDENT SHORTENING OF THE ACTION POTENTIAL IN MAMMALIAN VENTRICULAR MUSCLE [J].
BOYETT, MR ;
JEWELL, BR .
JOURNAL OF PHYSIOLOGY-LONDON, 1978, 285 (DEC) :359-380
[4]  
COOLEY JW, 1965, MATH COMPUT, V19, P27
[5]   EFFECTS OF PACING ON TRIGGERED ACTIVITY INDUCED BY EARLY AFTERDEPOLARIZATIONS [J].
DAMIANO, BP ;
ROSEN, MR .
CIRCULATION, 1984, 69 (05) :1013-1025
[6]  
DONALDSON RM, 1983, BRIT HEART J, V50, P213
[7]   STUDY OF THE ELECTRO-PHYSIOLOGICAL EFFECTS OF EARLY OR SUBENDOCARDIAL ISCHEMIA WITH INTRACAVITARY ELECTRODES IN THE DOG [J].
DONALDSON, RM ;
TAGGART, P ;
NASHAT, F ;
ABED, J ;
RICKARDS, AF ;
NOBLE, D .
CLINICAL SCIENCE, 1983, 65 (06) :579-588
[8]   ONLINE ANALYSIS OF INTRACELLULAR ELECTRO-PHYSIOLOGICAL DATA USING A MICROCOMPUTER SYSTEM [J].
ELHARRAR, V ;
LOVELACE, DE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1979, 237 (03) :H400-H408
[9]   CYCLE LENGTH DEPENDENCE OF HUMAN ACTION-POTENTIAL DURATION INVIVO - EFFECTS OF SINGLE EXTRASTIMULI, SUDDEN SUSTAINED RATE ACCELERATION AND DECELERATION, AND DIFFERENT STEADY-STATE FREQUENCIES [J].
FRANZ, MR ;
SWERDLOW, CD ;
LIEM, LB ;
SCHAEFER, J .
JOURNAL OF CLINICAL INVESTIGATION, 1988, 82 (03) :972-979
[10]   LONG-TERM RECORDING OF MONOPHASIC ACTION-POTENTIALS FROM HUMAN ENDOCARDIUM [J].
FRANZ, MR .
AMERICAN JOURNAL OF CARDIOLOGY, 1983, 51 (10) :1629-1634