DETERMINATION OF THE CORROSION RATES OF 6 DENTAL NICRMO ALLOYS IN AN ARTIFICIAL SALIVA BY CHEMICAL-ANALYSIS OF THE MEDIUM USING ICP-AES

被引:32
作者
MULLER, AWJ [1 ]
MAESSEN, FJMJ [1 ]
DAVIDSON, CL [1 ]
机构
[1] UNIV AMSTERDAM,DEPT DENT MAT SCI,1066 EA AMSTERDAM,NETHERLANDS
关键词
D O I
10.1016/0109-5641(90)90048-J
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
So that the influence of salivary components upon the corrosion rate of six dental NiCrMo alloys could be established, their mass loss was determined in a medium consisting of a modified Fusayama's artificial saliva to which 300 mg KSCN/L had been added (pH 5.0). Nickel was the main element released; its loss vs. immersion time curves on a log-log plot resembled straight lines. The total nickel losses after one week ranged from 0.4 to 12.5 μg/cm2. From the nickel loss, corrosion currents were calculated. The corrosion currents at 24 hours of immersion were up to 67% larger than the currents in a previous study of these alloys, where the medium consisted of a 20 mM KCl-5 mM phosphate buffer solution (pH 7). The alloys with the least molybdenum content showed the largest corrosion current increase. © 1990.
引用
收藏
页码:63 / 68
页数:6
相关论文
共 8 条
[1]  
Chana, Kuhn, A Critique of the Tuccillo-Nielsen Wheel Method for Tarnish Testing of Dental Alloys, J Dent, 12, pp. 314-318, (1984)
[2]  
Council on Dental Materials, Instrument and Equipment, Report on Base Metal Alloys for Crown and Bridge Applications: Benefits and Risks, J Am Dent Assoc, 111, pp. 479-483, (1985)
[3]  
Evans, The Corrosion and Oxidation of Metals, (1960)
[4]  
Geis-Gerstorfer, Sauer, Weber, Der Einflusz von Kaliumrhodanid auf das Korrosionsverhalten edelmetallfreier Dentallegierungen, Dtsch Zahnärtzl Z, 40, pp. 87-91, (1985)
[5]  
Meyer, Corrosion Resistance of Nickel-Chromium Dental Casting Alloys, Corr Sci, 17, pp. 971-982, (1977)
[6]  
Meyer, Nally, Influence of Artificial Salivas on the Corrosion of Dental Alloys, J Dent Res, 54, (1975)
[7]  
Muller, Davidson, Measurement of the Small Corrosion Current of a NiCr Alloy by the Potentiostatic Deaeration Method, J Electrochem Soc, 136, pp. 46-53, (1989)
[8]  
Muller, Maessen, Davidson, The Corrosion Rates of Five Dental NiCrMo Alloys Determined by Chemical Analysis of the Medium sing ICP-AES, and by the Potentiostatic Deareation Method, Corr Sci, (1990)