CONTINUOUS MEASUREMENT OF CARDIAC-OUTPUT WITH THE USE OF STOCHASTIC-SYSTEM IDENTIFICATION TECHNIQUES

被引:107
作者
YELDERMAN, M
机构
[1] InterFlo Medical, Piano, 75074, TX
来源
JOURNAL OF CLINICAL MONITORING | 1990年 / 6卷 / 04期
关键词
Measurement techniques: cardiac output;
D O I
10.1007/BF02842492
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The limitations of developing a technique to measure cardiac output continuously are given. Logical explanations are provided for the economic, technical, and physiologic benefits of a stochastic system identification technique for measuring cardiac output. Heat is supplied by a cathetermounted filament driven according to a pseudorandom binarsequence. Volumetric fluid flow is derived by a crosscorrelation algorithm written in the C language. In vitro validation is performed with water in a flow bench. The computed flow (y) compared with the in-line-measured flow (x) yields the linear regression y = 1.024x-0.157 (r = 0.99). The average coefficient of variation is less than 2% over a volumetric fluid flow range of 2 to 10 L/min. © 1990 Little, Brown and Company.
引用
收藏
页码:322 / 332
页数:11
相关论文
共 38 条
[1]  
Segal J., Pearl R.G., Ford A.J., Instantaneous and continuous cardiac output using a Doppler pulmonary artery catheter, J Am Coll Cardiol, 13, pp. 1382-1392, (1989)
[2]  
Abra J.H., Weber R.E., Holmen K.D., Transtracheal Doppler: a new procedure for continuous cardiac output measurement, Anesthesiology, 70, 1, pp. 134-138, (1989)
[3]  
Robson S.C., Murray A., Pearl I, et al. Reproducibility of cardiac output measurement by cross sectional and Doppler echocardiography, Br Heart J, 59, pp. 680-684, (1988)
[4]  
Evans J.M., Skidmore R., Luckman N.P., Wells P.N.T., A new approach to the noninvasive measurement of cardiac output using an annular array Doppler technique—I, Theoretical considerations and ultrasonic fields. Ultrasound Med Biol, 15, 3, pp. 169-178, (1989)
[5]  
Sorensen M.B., Bille-Brahe N.E., Engel H.C., Cardiac output measurement by thermal dilution: reproducibility and comparison with the dye-dilution technique, Ann Surg, 183, (1976)
[6]  
Stewart G.N., Researches on the circulation time and on the influences which affect it IV: the output of the heart, The Journal of Physiology, 22, pp. 159-183, (1897)
[7]  
Stewart G.N., The output of the heart in dogs, Am J Physiol, 57, pp. 27-50, (1921)
[8]  
Hamilton W.F., Moore J.W., Simultaneous determination of the pulmonary and systemic circulation times in man and of a figure related to the cardiac output, Am J Physiol, 84, (1928)
[9]  
Hamilton W.F., Moore J.W., Kinsman J.M., Spurling R.G., Studies on the circulation: IV. Further analysis of the injection method, and of changes in hemodynamics under physiological and pathological conditions, Am J Physiol, 99, pp. 534-551, (1932)
[10]  
Khalil H., Determination of cardiac output in man by a new method based on thermodilution, Lancet, 1, pp. 1352-1354, (1963)