CLEAR LENS EXTRACTION FOR THE CORRECTION OF HIGH REFRACTIVE ERROR

被引:51
作者
LYLE, WA
JIN, GJC
机构
[1] Eye Institute of Utah, Salt Lake City
关键词
CLEAR LENS EXTRACTION; HYPEROPIA; INTRAOCULAR LENS; MYOPIA; PHACOEMULSIFICATION; POSTERIOR CAPSULE OPACIFICATION;
D O I
10.1016/S0886-3350(13)80577-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The results of clear lens extraction and posterior chamber intraocular lens implantation in 31 eyes with high myopia and six eyes with high hyperopia were reviewed. In the myopic group, 77% of eyes achieved 20/40 or better uncorrected postoperative visual acuity and 97% achieved 20/40 or better corrected acuity. Sixty-eight percent of eyes were within 1.0 diopter (D) of emmetropia and 90% were within 2.0 D. Astigmatic keratotomy (four eyes) and radial keratotomy (one eye) were performed for postoperative refractive errors. Intraocular lens exchange was necessary to correct power in one case. In the hyperopic group, all six eyes achieved 20/40 or better uncorrected postoperative visual acuity and all were within 1.0 D of emmetropia. During the 20-month mean follow-up, no retinal detachment or cystoid macular edema was observed. Posterior capsule opacification was the major complication and it developed faster than reported in other studies.
引用
收藏
页码:273 / 276
页数:4
相关论文
共 19 条
[1]  
Waring GO, Lynn MJ, Nizam A, Et al., Results of the prospective evaluation of radial keratotomy (PERK) study five years after surgery, Ophthalmology, 98, pp. 1164-1176, (1991)
[2]  
Colin J, Mimouni F, Robinet A, Et al., The surgical treatment of high myopia: comparison of epikeratoplasty, keratomileusis and minus power anterior chamber lenses, Refract Corneal Surg, 6, pp. 245-251, (1990)
[3]  
Fechner PU, Heijde GL, Worst JGF, The correction of myopia by lens implantation into phakic eyes, Am J Ophthalmol, 107, pp. 659-663, (1989)
[4]  
Baikolf G, Joly P, Comparison of minus power anterior chamber intraocular lenses and myopic epikeratoplasty in phakic eyes, Refract Corneal Surg, 6, pp. 252-260, (1990)
[5]  
Mimouni F, Colin J, Koffi V, Bonnet P, Damage to the corneal endothelium from anterior chamber intraocular lenses in phakic myopic eyes, Refract Corneal Surg, 7, pp. 277-281, (1991)
[6]  
Saragoussi J-J, Cotinat J, Renard G, Et al., Damage to the corneal endothelium by minus power anterior chamber intraocular lenses, Refract Corneal Surg, 7, pp. 282-285, (1991)
[7]  
Verzella F, Refractive microsurgery of the lens in high myopia, Refract Corneal Surg, 6, pp. 273-275, (1990)
[8]  
Goldberg MF, Clear lens extraction for axial myopia
[9]  
an appraisal, Ophthalmology, 94, pp. 571-582, (1987)
[10]  
Colin J, Risk-benefit analysis of clear lensectomy and low-power posterior chamber intraocular lens for the correction of high myopia, Ophthalmology, 99, (1992)