DO EUROPEAN GSM MOBILE CELLULAR PHONES POSE A POTENTIAL RISK TO PACEMAKER PATIENTS

被引:68
作者
BARBARO, V [1 ]
BARTOLINI, P [1 ]
DONATO, A [1 ]
MILITELLO, C [1 ]
ALTAMURA, G [1 ]
AMMIRATI, F [1 ]
SANTINI, M [1 ]
机构
[1] SAN FILIPPO NERI HOSP,DEPT HEART DIS,ROME,ITALY
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1995年 / 18卷 / 06期
关键词
GSM CELLULAR PHONES; ELECTROMAGNETIC INTERFERENCE; IMPLANTED PACEMAKERS;
D O I
10.1111/j.1540-8159.1995.tb06961.x
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
A series of in vivo trials were carried out in order to verify whether the electromagnetic field radiated by GSM (Groupe Systemes Mobiles) mobile cellular phones might affect implanted pacemakers. Two European GSM phones of 2-watt power were tested and trials conducted on 101 pacemaker implanted outpatients attending day hospital for routine check-up, who volunteered for trials. Forty-three pacemaker models from 11 manufacturers were tested in all. When the sensing threshold of the pacemakers was set at a minimum and the antenna of the phone was in direct contact with the patient's chest, interference was detected for 26 implanted pacemakers. Specifically, pulse inhibition in 10 of 101 cases, ventricular triggering in 9 of 46 DDD-VDD pacemakers, and asynchronous pacing in 4 of 52 devices. Pulse inhibition was also observed combined with asynchronous pacing in 2 of 52 cases and with ventricular triggering in 2 of 46 cases. Minimum effect duration was ca. 3 seconds but in 6 cases effects continued as long as the interfering GSM signal was on. No permanent malfunctioning or changes in the programmed parameters were detected. Whenever interference was detected, trials were repeated to determine the maximum sensing threshold at which interference persisted (with the antenna in contact with the skin over the pacemaker). Then maximum distance between antenna and pacemaker at which interference occurred was determined at pacemaker maxim um and minimum sensing threshold. Under our experimental conditions electromagnetic interference effects were detected at a maximum distance of 10 cm with the pacemaker programmed at its minimum sensing threshold. When the phone antenna was in direct contact with patient's skin over the implant, electromagnetic interference effects occurred at maximum ventricular and atrial sensing thresholds of 4 mV and 2.5 mV, respectively.
引用
收藏
页码:1218 / 1224
页数:7
相关论文
共 10 条
[1]
Walter WH, Mitchell JC, Rustan PL, Et al., Cardiac pulse generators and electromagnetic interference, JAMA, 12, pp. 1628-1631, (1973)
[2]
Barbaro V, Bartolini P, Tarricone L., Evaluation of static magnetic field levels interfering with pacemakers, Physica Medica, 2, pp. 73-76, (1991)
[3]
Bonney CH, Rustan PL, Ford GE., Evaluation of effects of the microwaves oven (915 and 2450 MHz) and radar (2810 and 3050 MHz) electromagnetic radiation on noncompetitive cardiac pacemakers, IEEE Trans Biomedi Eng, 5, pp. 357-364, (1983)
[4]
Irnich W., Interference in pacemakers, PACE, 7, pp. 1021-1048, (1984)
[5]
Smith GS, Toler JC., Analysis of the coupling of electromagnetic interference to unipolar cardiac pacemakers, Med Biol Eng Comput, 19, pp. 97-109, (1981)
[6]
Barbaro V, Bartolini P, Donato A, Et al., pp. 275-276, (1994)
[7]
Parsonnet V, Furman S, Smith NPD., Implantable cardiac pacemaker: Status report and resource guidelines. A report of the Intersociety Commission for Heart Disease Resources, Am J Cardiol, 34, pp. 487-502, (1974)
[8]
Bernstein AD, Camm AJ, Fletcher RD, Et al., The NASPE/BPEG generic pacemaker code for antibradyarrythmia and adaptive‐rate pacing and antitachyarrythmia devices, PACE, 10, pp. 794-799, (1987)
[9]
Dechaux C, Scheller R., pp. 118-127, (1993)
[10]
Bursztejn J, Terminali GSM., pp. 128-140, (1993)