PLATELET DEPOSITION ONTO POLYMERIC SURFACES DURING SHUNTING

被引:13
作者
FUJIMOTO, K [1 ]
MINATO, M [1 ]
TADOKORO, H [1 ]
IKADA, Y [1 ]
机构
[1] KYOTO UNIV,BIOMED ENGN RES CTR,53 KAWAHARA CHO,SHOGO IN,SAKYO KU,KYOTO 606,JAPAN
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1993年 / 27卷 / 03期
关键词
D O I
10.1002/jbm.820270307
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In an attempt to develop blood-contacting tubes that can be applied for short-term uses with a reduced heparin concentration or, ideally, without heparinization, we evaluated the blood compatibility of polymeric materials with a rabbit ex vivo shunt model. The shunt tubes employed were made of silicone, plasticized poly(vinyl chloride) (PVC), and segmented poly(ether urethane) (PU). In addition, two kinds of surface-modified tube were used: poly(vinyl alcohol) (PVA)-coated PVC and poly(dimethylacrylamide) (PDMAA)-grafted PU. The ex vivo shunt results correlated well with protein adsorption and platelet adhesion in vitro. The following order for the extent of platelet deposition was given, irrespective of the blood-contacting duration: PDMAA-grafted PU < PVA-coated PVC < PU < silicone, PVC. It is likely that many platelet aggregates detached from the PVA-coated PVC surface. For PDMAA-grafted PU, no trace of detachment of aggregates could be detected on any of the SEM photographs. The number and morphology of blood cells adhered onto the tube surfaces during ex vivo shunting were dependent on the kind of polymer surfaces, the blood exposure time, and the flow rate of blood.
引用
收藏
页码:335 / 343
页数:9
相关论文
共 16 条
[1]  
FUJIMOTO K, 1990, ACS POLYM MATER SCI, V62, P736
[2]  
HANSON SR, 1980, J LAB CLIN MED, V95, P289
[3]  
Harker LA, 1982, BIOMATERIALS 1980, P519
[4]   PARALLEL FLOW ARTERIOVENOUS SHUNT FOR THE EXVIVO EVALUATION OF HEPARINIZED MATERIALS [J].
IP, WF ;
ZINGG, W ;
SEFTON, MV .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1985, 19 (02) :161-178
[5]   THE INTERACTION OF BLOOD COMPONENTS WITH PDMS (POLYDIMETHYLSILOXANE) AND LDPE (LOW-DENSITY POLYETHYLENE) IN A BABOON EXVIVO ARTERIOVENOUS SHUNT MODEL [J].
KEOUGH, EM ;
MACKEY, WC ;
CONNOLLY, R ;
FOXALL, T ;
RAMBERGLASKARIS, K ;
MCCULLOUGH, JL ;
ODONNELL, TF ;
CALLOW, AD .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1985, 19 (05) :577-587
[6]  
KIM K, 1989, SURG RES COMM, V6, P289
[7]   A CANINE EXVIVO SERIES SHUNT FOR EVALUATING THROMBUS DEPOSITION ON POLYMER SURFACES [J].
LELAH, MD ;
LAMBRECHT, LK ;
COOPER, SL .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1984, 18 (05) :475-496
[8]   PHYSICOCHEMICAL CHARACTERIZATION AND INVIVO BLOOD TOLERABILITY OF CAST AND EXTRUDED BIOMER [J].
LELAH, MD ;
LAMBRECHT, LK ;
YOUNG, BR ;
COOPER, SL .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1983, 17 (01) :1-22
[9]   A BABOON FLOW-REGULATED SHUNT FOR THE STUDY OF SMALL CALIBER VASCULAR GRAFTS [J].
MACKEY, WC ;
KEOUGH, EM ;
CONNOLLY, RJ ;
MCCULLOUGH, JL ;
RAMBERGLASKARIS, K ;
ODONNELL, TF ;
FOXALL, T ;
CALLOW, AD .
JOURNAL OF SURGICAL RESEARCH, 1984, 37 (02) :112-118
[10]  
NOJIRI C, 1987, T AM SOC ART INT ORG, V33, P596