MEASUREMENT OF SKELETAL-MUSCLE MOTION IN-VIVO WITH PHASE-CONTRAST MR-IMAGING

被引:35
作者
DRACE, JE [1 ]
PELC, NJ [1 ]
机构
[1] STANFORD UNIV, MED CTR, DEPT DIAGNOST RADIOL, STANFORD, CA 94305 USA
关键词
MOTION STUDIES; MUSCLES; PHASE IMAGING;
D O I
10.1002/jmri.1880040211
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The ability to measure skeletal muscle motion with phase-contrast magnetic resonance (MR) imaging was tested with a motion phantom that simulated muscle activity. Quantitative analytic data on unidimensional, bidirectional skeletal muscle motion measured in vivo was obtained in four healthy volunteers. MR images of the subjects' forearms were obtained during flexion and extension of the fingers and of the anterior and posterior muscle compartments of the lower leg with various resistances to ankle dorsiflexion and plantar flexion. It was necessary to correct the data for the effects of eddy currents. In vitro evaluation of the technique was done by studying through-plane sinusoidal motion of solid objects. The largest error was underestimation of the peak excursion of 11.5 mm by 0.09 mm (the root mean square error for the cycle was 0.04 mm) In vivo experiments demonstrated the contraction of muscles in relation to each other. Data acquisition and analysis techniques must be refined, but measuring skeletal muscle motion with phase-contrast MR imaging should enhance the understanding of bioengineering fundamentals and muscular changes in disease and adaptation.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 17 条
[1]   MR IMAGING OF MOTION WITH SPATIAL MODULATION OF MAGNETIZATION [J].
AXEL, L ;
DOUGHERTY, L .
RADIOLOGY, 1989, 171 (03) :841-845
[2]  
Boyce F M, 1991, Res Publ Assoc Res Nerv Ment Dis, V69, P121
[3]  
COLE TM, 1990, REPORT TASK FORCE ME
[4]  
DUBOWITZ V, 1991, Acta Paediatrica Japonica, V33, P198
[5]   CONGENITAL MUSCULAR-DYSTROPHIES [J].
FENICHEL, GM .
NEUROLOGIC CLINICS, 1988, 6 (03) :519-528
[6]   A MUSCULOSKELETAL MODEL OF THE HUMAN LOWER-EXTREMITY - THE EFFECT OF MUSCLE, TENDON, AND MOMENT ARM ON THE MOMENT ANGLE RELATIONSHIP OF MUSCULOTENDON ACTUATORS AT THE HIP, KNEE, AND ANKLE [J].
HOY, MG ;
ZAJAC, FE ;
GORDON, ME .
JOURNAL OF BIOMECHANICS, 1990, 23 (02) :157-169
[7]  
MANKTELOW RT, 1988, HAND CLIN, V4, P289
[8]   NMR BLOOD-FLOW IMAGING USING MULTIECHO, PHASE-CONTRAST SEQUENCES [J].
ODONNELL, M .
MEDICAL PHYSICS, 1985, 12 (01) :59-64
[9]  
PELC N J, 1991, Magnetic Resonance Quarterly, V7, P229
[10]   ENCODING STRATEGIES FOR 3-DIRECTION PHASE-CONTRAST MR IMAGING OF FLOW [J].
PELC, NJ ;
BERNSTEIN, MA ;
SHIMAKAWA, A ;
GLOVER, GH .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (04) :405-413