DETERMINATION OF GAS TEMPERATURES AT 295-K-1273-K USING CO VIBRATIONAL-ROTATIONAL ABSORPTION-SPECTRA RECORDED WITH AN FT-IR SPECTROMETER

被引:6
作者
MEDVECZ, PJ
NICHOLS, KM
CLAY, DT
ATALLA, R
机构
[1] INST PAPER SCI & TECHNOL,575 14TH ST NW,ATLANTA,GA 30318
[2] JAMES RIVER CORP,NEENAH,WI
[3] FOREST PROD LAB,MADISON,WI
关键词
INFRARED; FT-IR; CO; ABSORPTION SPECTRA; TEMPERATURE ANALYSIS; COMBUSTION GASES;
D O I
10.1366/0003702914335779
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Fourier transform infrared absorption spectroscopy has been used to determine the rotational temperatures of high-temperature (less-than-or-equal-to 1273 K) CO/N2 gas samples. To achieve this objective, a special gas cell was constructed which permitted the acquisition of absorption spectra of samples containing CO at concentrations of 1-10% by volume in N2 and at temperatures between 295 and 1273 K. The absorption spectra were recorded with the use of a moderate-resolution (0.25 cm-1) FT-IR spectrometer. The rotational temperatures were calculated from the spectra after rigorous correction for photometric errors. Temperatures calculated from the P branch of CO spectra had accuracies of 3.2% or better. In all cases, the calculated temperatures were lower than temperatures recorded with a thermocouple, which had an accuracy of +/- 0.75%. An important factor in the success of these determinations was the adoption of measures to prevent the modulated spectral emission of the hot gases from reaching the detector.
引用
收藏
页码:1350 / 1359
页数:10
相关论文
共 12 条
[1]   ERRORS IN ABSORBANCE MEASUREMENTS IN INFRARED FOURIER-TRANSFORM SPECTROMETRY BECAUSE OF LIMITED INSTRUMENT RESOLUTION [J].
ANDERSON, RJ ;
GRIFFITHS, PR .
ANALYTICAL CHEMISTRY, 1975, 47 (14) :2339-2347
[2]   DETERMINATION OF ROTATIONAL TEMPERATURES OF DIATOMIC-MOLECULES FROM ABSORPTION-SPECTRA MEASURED AT MODERATE RESOLUTION [J].
ANDERSON, RJ ;
GRIFFITHS, PR .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1977, 17 (03) :393-401
[3]   MEASUREMENT OF ROTATIONAL TEMPERATURE AND DISSOCIATION IN N2O GLOW-DISCHARGES USING INSITU FOURIER-TRANSFORM INFRARED-SPECTROSCOPY [J].
CLELAND, TA ;
HESS, DW .
JOURNAL OF APPLIED PHYSICS, 1988, 64 (03) :1068-1077
[4]  
GRIFFITHS PR, 1986, FOURIER TRANSFORM IN, P18
[5]  
GROSS LA, 1985, INFRARED METHODS GAS, pCH3
[6]   ACCURATE CALCULATED TABULATIONS OF CO LINE BROADENING BY H2O, N2, O2, AND CO2 IN THE 200-3000-K TEMPERATURE-RANGE [J].
HARTMANN, JM ;
ROSENMANN, L ;
PERRIN, MY ;
TAINE, J .
APPLIED OPTICS, 1988, 27 (15) :3063-3065
[7]   MEASUREMENTS OF INTENSITIES AND SELF-GAS AND FOREIGN-GAS-BROADENED HALF-WIDTHS OF SPECTRAL-LINES IN THE CO FUNDAMENTAL-BAND [J].
NAKAZAWA, T ;
TANAKA, M .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1982, 28 (05) :409-416
[8]   FOURIER-TRANSFORM INFRARED (FT-IR) MEASUREMENTS IN SOOTING FLAMES [J].
OTTESEN, DK ;
STEPHENSON, DA .
COMBUSTION AND FLAME, 1982, 46 (01) :95-104
[9]  
OTTESEN DK, 1985, P INT C COAL SCI, P351
[10]  
SOLOMON PR, 1982, 19TH S INT COMB PITT