ONLINE REVERSED PHASE LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY

被引:52
作者
KARGER, BL [1 ]
KIRBY, DP [1 ]
VOUROS, P [1 ]
FOLTZ, RL [1 ]
HIDY, B [1 ]
机构
[1] BATTELLE MEM INST,COLUMBUS LABS,COLUMBUS,OH 43201
关键词
D O I
10.1021/ac50050a008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The addition of a modified segmented-flow extractor between a liquid chromatograph (LC) and a mass spectrometer (MS) permits the direct coupling of an LC, operated in the reversed phase mode, to an MS without compromising the operational characteristics of either. This combination is accomplished by the extraction of solutes into a volatile organic solvent, which is then transported into the MS via a moving belt interface. The system has been tested with a mobile phase consisting of 40-60 (v/v) MeOH-H2O, 0.1 M NaH2PO4, pH 2.5 at a flow rate of 0.5 mL/min and was operated for a significant period of time with no deterioration of the performance of the MS. The applicability of the interface to the analysis of carbamate pesticides has been examined. The effects of the interface on peak broadening and sample recovery have also been examined. This system provides a means of performing reversed phase liquid chromatography, even with nonvolatile buffers, in an on-line combination with an MS. © 1979, American Chemical Society. All rights reserved.
引用
收藏
页码:2324 / 2328
页数:5
相关论文
共 13 条
  • [1] LIQUID CHROMATOGRAPHY MASS SPECTROMETRY .2. CONTINUOUS MONITORING
    ARPINO, P
    BALDWIN, MA
    MCLAFFERTY, FW
    [J]. BIOMEDICAL MASS SPECTROMETRY, 1974, 1 (01): : 80 - 82
  • [2] ARPINO PJ, 1979, ANAL CHEM, V51, pA682
  • [3] CROSSED-BEAM LIQUID CHROMATOGRAPH MASS SPECTROMETER COMBINATION
    BLAKLEY, CR
    MCADAMS, MJ
    VESTAL, ML
    [J]. JOURNAL OF CHROMATOGRAPHY, 1978, 158 (OCT): : 261 - 276
  • [4] ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY - CORONA DISCHARGE ION-SOURCE FOR USE IN LIQUID CHROMATOGRAPH MASS SPECTROMETER-COMPUTER ANALYTICAL SYSTEM
    CARROLL, DI
    DZIDIC, I
    STILLWELL, RN
    HAEGELE, KD
    HORNING, EC
    [J]. ANALYTICAL CHEMISTRY, 1975, 47 (14) : 2369 - 2373
  • [5] CONTINUOUS-FLOW AUTOMATED HPLC ANALYSIS OF FAT-SOLUBLE VITAMINS IN TABLETS
    DOLAN, JW
    GANT, JR
    TANAKA, N
    GIESE, RW
    KARGER, BL
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1978, 16 (12) : 616 - 622
  • [6] LIQUID CHROMATOGRAPH MASS SPECTROMETER INTERFACE
    JONES, PR
    YANG, SK
    [J]. ANALYTICAL CHEMISTRY, 1975, 47 (07) : 1000 - 1003
  • [7] KARGER B L, 1978, Analytical Chemistry, V50, p1048A, DOI 10.1021/ac50034a001
  • [8] EXTRACTION DETECTOR FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING SOLVENT SEGMENTATION OF THE COLUMN EFFLUENT
    LAWRENCE, JF
    BRINKMAN, UAT
    FREI, RW
    [J]. JOURNAL OF CHROMATOGRAPHY, 1979, 171 (APR): : 73 - 80
  • [9] DIRECT ANALYSIS OF LIQUID-CHROMATOGRAPHIC EFFLUENTS
    MCFADDEN, WH
    SCHWARTZ, HL
    EVANS, S
    [J]. JOURNAL OF CHROMATOGRAPHY, 1976, 122 (JUL7): : 389 - 396
  • [10] INTERFACE FOR ONLINE LIQUID CHROMATOGRAPHY MASS SPECTROSCOPY ANALYSIS
    SCOTT, RPW
    SCOTT, CG
    MUNROE, M
    HESS, J
    [J]. JOURNAL OF CHROMATOGRAPHY, 1974, 99 (NOV6): : 395 - 405