THE CONTINUOUS LOW-DOSE INSULIN AND GLUCOSE-INFUSION TEST - A SIMPLIFIED AND ACCURATE METHOD FOR THE EVALUATION OF INSULIN SENSITIVITY AND INSULIN-SECRETION IN POPULATION STUDIES

被引:26
作者
PIATTI, PM
MONTI, LD
CAUMO, A
SANTAMBROGIO, G
MAGNI, F
GALLIKIENLE, M
COSTA, S
PONTIROLI, AE
ALBERTI, KGMM
POZZA, G
机构
[1] UNIV MILAN, DIPARTIMENTO CHIM & BIOCHIM MED, MILAN, ITALY
[2] MED SCH NEWCASTLE UPON TYNE, DEPT MED, NEWCASTLE UPON TYNE NE2 4HH, TYNE & WEAR, ENGLAND
关键词
D O I
10.1210/jc.80.1.34
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In this study we investigated a simple nonlabor-intensive method to evaluate insulin sensitivity and beta-cell function which is suitable for application in population studies. The method is a refinement of the modified Harano test and consists of a continuous low dose insulin (25 mU/kg.h) and glucose (4 mg/kg.min) infusion test (LDIGIT) lasting 150 min. Insulin sensitivity was evaluated as the MCR of glucose divided by the steady state serum insulin level achieved at the end of the test. Insulin secretion was expressed as the incremental area for C-peptide concentration during the first 15 min of the test. We compared the indices of insulin sensitivity and insulin secretion yielded by LDIGIT with those derived from the euglycemic clamp and the hyperglycemic clamp, respectively. Fifty-four subjects underwent a LDIGIT (33 with normal glucose tolerance and 21 with impaired glucose tolerance); of the 54, 19 were submitted to a euglycemic clamp, 18 to a hyperglycemic clamp, and 10 to a modified Harano test (insulin infusion, 50 mU/kg.h; glucose infusion, 6 mg/kg.min). LDIGIT overcame the drawbacks associated with the modified Harano test because it resulted in more stable final glucose levels and prevented the occurrence of hypoglycemic episodes. No significant differences were found between the insulin sensitivity index (ISI) of the LDIGIT and that of the euglycemic clamp for each group of subjects. Moreover, there was a strong correlation between the ISI determined by LDIGIT and the ISI determined by clamp (r = 0.90; P < 0.0001), and the best regression line was not different from the identity line, suggesting that the two indices are equivalent. The index of insulin secretion provided by LDIGIT correlated well with that of the hyperglycemic clamp (r = 0.82; P < 0.001) and was significantly higher in overweight subjects than in normal weight subjects. In conclusion, LDIGIT is a simple and accurate method to assess insulin sensitivity and secretion. It can be useful in population studies and in situations when more complex techniques are not feasible.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 24 条
[1]   IMPORTANCE OF GLUCOSE PER SE TO INTRAVENOUS GLUCOSE-TOLERANCE - COMPARISON OF THE MINIMAL-MODEL PREDICTION WITH DIRECT MEASUREMENTS [J].
ADER, M ;
PACINI, G ;
YANG, YJ ;
BERGMAN, RN .
DIABETES, 1985, 34 (11) :1092-1103
[2]   ASSESSMENT OF INSULIN SENSITIVITY INVIVO [J].
BERGMAN, RN ;
FINEGOOD, DT ;
ADER, M .
ENDOCRINE REVIEWS, 1985, 6 (01) :45-86
[3]   TOWARD PHYSIOLOGICAL UNDERSTANDING OF GLUCOSE-TOLERANCE - MINIMAL-MODEL APPROACH [J].
BERGMAN, RN .
DIABETES, 1989, 38 (12) :1512-1527
[4]   EQUIVALENCE OF THE INSULIN SENSITIVITY INDEX IN MAN DERIVED BY THE MINIMAL MODEL METHOD AND THE EUGLYCEMIC GLUCOSE CLAMP [J].
BERGMAN, RN ;
PRAGER, R ;
VOLUND, A ;
OLEFSKY, JM .
JOURNAL OF CLINICAL INVESTIGATION, 1987, 79 (03) :790-800
[5]   PHYSIOLOGIC EVALUATION OF FACTORS CONTROLLING GLUCOSE-TOLERANCE IN MAN - MEASUREMENT OF INSULIN SENSITIVITY AND BETA-CELL GLUCOSE SENSITIVITY FROM THE RESPONSE TO INTRAVENOUS GLUCOSE [J].
BERGMAN, RN ;
PHILLIPS, LS ;
COBELLI, C .
JOURNAL OF CLINICAL INVESTIGATION, 1981, 68 (06) :1456-1467
[6]   TRACER-TO-TRACEE RATIO FOR ANALYSIS OF STABLE ISOTOPE TRACER DATA - LINK WITH RADIOACTIVE KINETIC FORMALISM [J].
COBELLI, C ;
TOFFOLO, G ;
FOSTER, DM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 262 (06) :E968-E975
[7]  
DAVIS BM, 1979, DIABETES, V28, P32
[8]  
DEFRONZO RA, 1979, AM J PHYSIOL, V237, pE214
[9]   ESTIMATION OF ENDOGENOUS GLUCOSE-PRODUCTION DURING HYPERINSULINEMIC-EUGLYCEMIC GLUCOSE CLAMPS - COMPARISON OF UNLABELED AND LABELED EXOGENOUS GLUCOSE INFUSATES [J].
FINEGOOD, DT ;
BERGMAN, RN ;
VRANIC, M .
DIABETES, 1987, 36 (08) :914-924
[10]   FURTHER EVIDENCE THAT INSULIN RESISTANCE EXISTS IN PATIENTS WITH CHEMICAL DIABETES [J].
GINSBERG, H ;
OLEFSKY, JM ;
REAVEN, GM .
DIABETES, 1974, 23 (08) :674-678