2-CHANNEL FIBER OPTIC SKIN ERYTHEMA METER

被引:17
作者
KOPOLA, H
LAHTI, A
MYLLYLA, RA
HANNUKSELA, M
机构
[1] UNIV OULU,DERMATOL CLIN,SF-90220 OULU,FINLAND
[2] TECH RES CTR FINLAND,OPTOELECTR LAB,SF-90571 OULU,FINLAND
关键词
BIOMEDICAL OPTICS; SKIN REFLECTANCE; ERYTHEMA; FIBER OPTIC SENSORS; IRRITANCY TESTING; OPTICAL SENSING; COLOR RECOGNITION;
D O I
10.1117/12.60743
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The skin erythema meter is a fiber optic, dual-wavelength reflectance meter that measures the reflectance of the skin on two wave-lengths, one the blood/hemoglobin absorption band (555 nm) and another a reference (660 nm). The instrument consists of a fiber optic sensor head, a microprocessor-based control and analysis unit, and a plotter, and it presents the relation between the measured reflectance results in terms of a reflectance index [R(555 nm):R(660 nm)]. The measurement cycle, including printing, takes 5 s. Stability tests on the erythema meter (constant distance, reference object) showed the standard deviation of the reflectance index to be +/- 0.1%, whereas that in repeatability tests was less than +/- 0.5% for skin and less than +/- 0.2% for paper with hand-held positioning and repetition. The dynamic change in the reflectance index was about 30% with strong irritation. Results of various irritation test series or human skin are also presented. Finally, the performance and applicability of the skin erythema meter with respect to allergy test procedures, irritancy testing, and measurement of uv-induced erythema are discussed.
引用
收藏
页码:222 / 226
页数:5
相关论文
共 20 条
[1]   THE OPTICS OF HUMAN-SKIN [J].
ANDERSON, RR ;
PARRISH, JA .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1981, 77 (01) :13-19
[2]  
Blanken R, 1986, Derm Beruf Umwelt, V34, P5
[3]   REFLECTION SPECTROPHOTOMETRY - USE IN EVALUATION OF SKIN PIGMENTARY DISTURBANCES [J].
BUCKLEY, WR ;
GRUM, F .
ARCHIVES OF DERMATOLOGY, 1961, 83 (02) :249-&
[4]   A THEORETICAL AND EXPERIMENTAL-STUDY OF LIGHT-ABSORPTION AND SCATTERING BY INVIVO SKIN [J].
DAWSON, JB ;
BARKER, DJ ;
ELLIS, DJ ;
GRASSAM, E ;
COTTERILL, JA ;
FISHER, GW ;
FEATHER, JW .
PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04) :695-709
[5]   A PORTABLE INSTRUMENT FOR QUANTIFYING ERYTHEMA INDUCED BY ULTRAVIOLET-RADIATION [J].
DIFFEY, BL ;
OLIVER, RJ ;
FARR, PM .
BRITISH JOURNAL OF DERMATOLOGY, 1984, 111 (06) :663-672
[6]  
FARR P, 1984, BRIT J DERMATOL, V3, P673
[7]  
KOPOLA H, 1990, P SOC PHOTO-OPT INS, V1201, P345, DOI 10.1117/12.17557
[8]  
Kopola H., 1986, Proceedings of the SPIE - The International Society for Optical Engineering, V586, P204, DOI 10.1117/12.951165
[9]  
KOPOLA H, 1988, ACTA U OUL C, V45
[10]   SKIN REFLECTANCE MEASUREMENTS OF PATCH TEST RESPONSES [J].
MENDELOW, AY ;
FORSYTH, A ;
FEATHER, JW ;
BAILLIE, AJ ;
FLORENCE, AT .
CONTACT DERMATITIS, 1986, 15 (02) :73-78