DEVELOPMENT OF AN ADVANCED DIGITAL IMAGE-PROCESSOR FOR REAL-TIME SPECKLE SUPPRESSION IN ROUTINE ULTRASONIC-SCANNING

被引:10
作者
LOUPAS, T
MCDICKEN, WN
ANDERSON, T
ALLAN, PL
机构
[1] UNIV EDINBURGH,ROYAL INFIRM,DEPT MED RADIOL,EDINBURGH EH3 9YW,MIDLOTHIAN,SCOTLAND
[2] UNIV EDINBURGH,ROYAL INFIRM DEPT MED PHYS & MED ENGN,EDINBURGH EH3 9YW,MIDLOTHIAN,SCOTLAND
关键词
ULTRASOUND IMAGING; SPECKLE; DIGITAL FILTERS; HARDWARE ARCHITECTURES; REAL-TIME IMAGE PROCESSING;
D O I
10.1016/0301-5629(94)90064-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper describes a digital image processor for ultrasonic speckle suppression that was explicitly designed to satisfy the requirements of detail preservation, adequate smoothing and real-time operation. The first two of these requirements were addressed by selecting a nonlinear adaptive algorithm, which uses a measure of local homogeneity to adjust the amount of smoothing performed at each point of the scan, and employing a large (9 x 9 pixels) filtering window. Real-time operation was achieved by developing a highly concurrent systolic architecture that allowed the efficient mapping of the algorithm into low-cost high-density hardware. Initial experience, obtained by interfacing the processor to a scanner, suggests that this type of processing is capable of enhancing the visibility of subtle differences in echogenicity while retaining genuine image detail, as judged by the preservation of the small vessels and ducts. In addition to its impact on contrast resolution, this form of real-time speckle suppression should also prove valuable as a preprocessing stage before performing other digital image processing operations that are sensitive to noise, such as segmentation and three-dimensional rendering.
引用
收藏
页码:239 / 249
页数:11
相关论文
共 37 条
[1]   ADAPTIVE FILTERING FOR REDUCTION OF SPECKLE IN ULTRASONIC PULSE-ECHO IMAGES [J].
BAMBER, JC ;
DAFT, C .
ULTRASONICS, 1986, 24 (01) :41-44
[2]   REAL-TIME IMPLEMENTATION OF COHERENT SPECKLE SUPPRESSION IN B-SCAN IMAGES [J].
BAMBER, JC ;
PHELPS, JV .
ULTRASONICS, 1991, 29 (03) :218-224
[3]  
BAMBER JC, 1987, SPIE P, V768, P120
[4]  
BAMBER JC, 1989, SPIE, V1092, P33
[5]   SPECKLE IN ULTRASOUND B-MODE SCANS [J].
BURCKHARDT, CB .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (01) :1-6
[6]   VISUAL IMPACT OF ADAPTIVE SPECKLE REDUCTION ON US B-MODE IMAGES [J].
CRAWFORD, DC ;
COSGROVE, DO ;
TOHNO, E ;
SVENSSON, WE ;
ALMURRANI, B ;
BELL, DS ;
STEPNIEWSKA, K ;
BAMBER, JC .
RADIOLOGY, 1992, 183 (02) :555-561
[7]   COMPENSATION FOR THE SIGNAL-PROCESSING CHARACTERISTICS OF ULTRASOUND B-MODE SCANNERS IN ADAPTIVE SPECKLE REDUCTION [J].
CRAWFORD, DC ;
BELL, DS ;
BAMBER, JC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (06) :469-485
[8]  
CRAWFORD DC, 1990, P IEEE ULTR S, P1589
[9]  
DING R, 1987, IEEE T CIRCUITS SYST, V34, P948, DOI 10.1109/TCS.1987.1086226
[10]   DIGIT-SERIAL PROCESSING TECHNIQUES [J].
HARTLEY, R ;
CORBETT, P .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS, 1990, 37 (06) :707-719