ANALYSIS OF POLAR THERMALLY LABILE PESTICIDES USING DIFFERENT SOLID-PHASE EXTRACTION (SPE) MATERIALS WITH GC AND HPLC TECHNIQUES

被引:24
作者
EISERT, R [1 ]
LEVSEN, K [1 ]
WUNSCH, G [1 ]
机构
[1] UNIV HANNOVER,INST INORGAN & ANALYT CHEM,D-30167 HANNOVER,GERMANY
关键词
PESTICIDES; WATER ANALYSIS; SOLID-PHASE EXTRACTION (SPE); GC-AED; THERMOSPRAY LC-MS; ATOMIC EMISSION DETECTOR;
D O I
10.1080/03067319508033117
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present study, an efficient method for extraction, separation and determination of a limited number (30) of polar pesticides in aqueous matrices has been developed. Pesticides were extracted with high recoveries (usually >85%) from 1 L water samples, using the solid-phase extraction (SPE) technique. Affinities to different SPE materials (C-18 and XAD resins) have been studied for all pesticides. Special attention has been paid to the following 5 pesticides (which have classified by the EC as compounds which are particularly difficult to analyse): benazolin, bromofenoxim, ethofumesate, fenamiphos and phenmedipham. Thermally labile compounds have been determined with high pressure liquid chromatography (HPLC) and UV detection in comparison to TSP-LC-MS. Absolute limits of detection (LODs) for the HPLC technique are usually below 1 ng at 220 nm. Thermospray LC-MS determination shows usually limits of detection of 1-10 ng (SCAN) and 60-800 pg (SIM). All pesticides, which are amenable to GC have been detected in a comparative study with the following detectors: flame ionization detector (FID), nitrogen-phosphorus detector (NPD), electron capture detector (ECD) and atomic emission detector (AED). Element-specific detection of various functional groups of these pesticides has been achieved using GC-AED. Thus, while the FID has the lowest specificity, the AED is the most specific detector. LODs are usually <300 pg (FID < 20 pg, NPD < 1 pg, ECD < 1 pg, AED < 300 pg). Spiked river water samples (from the River Leine and River Weser in Lower Saxony, Germany) have been used to test the employed method. With the spiked surface water samples recoveries were usually >80%.
引用
收藏
页码:103 / 120
页数:18
相关论文
共 11 条
  • [1] OCCURRENCE OF 38 PESTICIDES IN VARIOUS FRENCH SURFACE AND GROUND WATERS
    LEGRAND, MF
    COSTENTIN, E
    BRUCHET, A
    [J]. ENVIRONMENTAL TECHNOLOGY, 1991, 12 (11) : 985 - 996
  • [2] LEVSEN K, 1993, ACTA HYDROCH HYDROB, V3, P153
  • [3] RAPID SCREENING OF A LARGE GROUP OF POLAR PESTICIDES IN RIVER WATER BY ONLINE TRACE ENRICHMENT AND COLUMN LIQUID-CHROMATOGRAPHY
    LISKA, I
    BROUWER, ER
    OSTHEIMER, AGL
    LINGEMAN, H
    BRINKMAN, UAT
    GEERDINK, RB
    MULDER, WH
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1992, 47 (04) : 267 - 291
  • [4] EVALUATION OF A MICROWAVE CAVITY, DISCHARGE-TUBE, AND GAS-FLOW SYSTEM FOR COMBINED GAS-CHROMATOGRAPHY ATOMIC EMISSION DETECTION
    QUIMBY, BD
    SULLIVAN, JJ
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (10) : 1027 - 1034
  • [5] DETERMINATION OF NITROGEN-CONTAINING PESTICIDES BY HPLC WITH DIODE-ARRAY DETECTION
    REUPERT, R
    PLOGER, E
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 331 (05): : 503 - 509
  • [6] Reupert R, 1989, VOM WASSER, V72, P211
  • [7] THERMOSPRAY MASS-SPECTRAL STUDIES OF PESTICIDES - TEMPERATURE AND SALT CONCENTRATION EFFECTS ON THE ION ABUNDANCES IN THERMOSPRAY MASS-SPECTRA
    VOLMER, D
    PREISS, A
    LEVSEN, K
    WUNSCH, G
    [J]. JOURNAL OF CHROMATOGRAPHY, 1993, 647 (02): : 235 - 259
  • [8] VOLMER D, 1994, J CHROMATOGR, V600, P231
  • [9] WYLIE PL, 1989, HRC-J HIGH RES CHROM, V12, P813
  • [10] 1991, 27 EC WAT POLL RES R