3-LEVEL SCREENING DESIGNS FOR THE OPTIMIZATION OR THE RUGGEDNESS TESTING OF ANALYTICAL PROCEDURES

被引:35
作者
VANDERHEYDEN, Y [1 ]
KHOTS, MS [1 ]
MASSART, DL [1 ]
机构
[1] VRIJE UNIV BRUSSELS, INST FARMACEUT, LAARBEEKLAAN 103, B-1090 BRUSSELS, BELGIUM
关键词
RUGGEDNESS TESTING; OPTIMIZATION;
D O I
10.1016/0003-2670(93)85055-O
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several Plackett-Burman designs have been proposed as screening designs for the optimisation or the ruggedness testing of a test procedure. One of these, a three-level design, described in the literature can lead to wrong conclusions about the influence of the different factors due to the construction of the design. When three levels of the variables that may have an influence on the test procedure require examination, one should use a reflected two-level design or a well balanced three-level design. A proposal for the latter is given.
引用
收藏
页码:189 / 195
页数:7
相关论文
共 9 条
[1]   STATISTICAL DESIGN APPLIED TO PRODUCT DESIGN [J].
HUNTER, JS .
JOURNAL OF QUALITY TECHNOLOGY, 1985, 17 (04) :210-221
[2]   OPTIMIZATION PROCEDURE FOR THE SILANIZATION OF SILICAS FOR REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .2. DETAILED EXAMINATION OF SIGNIFICANT VARIABLES [J].
JONES, K .
JOURNAL OF CHROMATOGRAPHY, 1987, 392 :11-16
[3]   OPTIMIZATION PROCEDURE FOR THE SILANIZATION OF SILICAS FOR REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. ELIMINATION OF NONSIGNIFICANT VARIABLES [J].
JONES, K .
JOURNAL OF CHROMATOGRAPHY, 1987, 392 :1-10
[4]  
JONES K, 1986, INT LAB, V16, P32
[5]  
MORGAN E, 1991, CHEMOMETRICS EXPT DE, P110
[6]  
Plackett R.L., 1946, BIOMETRIKA, V33, P305, DOI [10.1093/biomet/33.4.305, DOI 10.2307/2332195, DOI 10.1093/BIOMET/33.4.305]
[7]   RES, AN EXPERT SYSTEM FOR THE SET-UP AND INTERPRETATION OF A RUGGEDNESS TEST IN HPLC METHOD VALIDATION .2. THE RUGGEDNESS EXPERT SYSTEM [J].
VANLEEUWEN, JA ;
BUYDENS, LMC ;
VANDEGINSTE, BGM ;
KATEMAN, G ;
SCHOENMAKERS, PJ ;
MULHOLLAND, M .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1991, 11 (01) :37-55
[8]   RES, AN EXPERT SYSTEM FOR THE SET-UP AND INTERPRETATION OF A RUGGEDNESS TEST IN HPLC METHOD VALIDATION .1. THE RUGGEDNESS TEST IN HPLC METHOD VALIDATION [J].
VANLEEUWEN, JA ;
BUYDENS, LMC ;
VANDEGINSTE, BGM ;
KATEMAN, G ;
SCHOENMAKERS, PJ ;
MULHOLLAND, M .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1991, 10 (03) :337-347
[9]   RESOLUTION OPTIMIZATION IN MICELLAR ELECTROKINETIC CHROMATOGRAPHY - USE OF PLACKETT-BURMAN STATISTICAL DESIGN FOR THE ANALYSIS OF TESTOSTERONE ESTERS [J].
VINDEVOGEL, J ;
SANDRA, P .
ANALYTICAL CHEMISTRY, 1991, 63 (15) :1530-1536