EFFECT OF THE BEAM-VESSEL ANGLE ON THE RECEIVED ACOUSTIC-SIGNAL FROM BLOOD

被引:12
作者
FERRARA, KW
机构
[1] CALIF STATE UNIV SACRAMENTO,DEPT ELECT ENGN,SACRAMENTO,CA 95819
[2] UNIV CALIF DAVIS,CTR IMAGE PROC & INTEGRATED COMPUTING,DAVIS,CA 95616
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
D O I
10.1109/58.384452
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In order to explore the feasibility of algorithms to determine the three dimensional (3D) velocity magnitude from the received ultrasonic blood echo from a single line of sight, the signal from small sample volumes is studied as a function of beam-vessel angle. As opposed to previous treatments of the effect of the beam-vessel angle on the received acoustic signal, a wideband signal is transmitted and the returned signal in each sample volume is analyzed. High-resolution experimental M-mode images of radio-frequency (rf) echo signals are used to visualize the dow in individual regions of interest. These experiments confirm the predictions of a theoretical model for the signal and its second moment. It is shown that the two major effects limiting the correlated signal interval are the spread of axial velocities within the sample volume and the transit time across the lateral beam width. Particularly for small beam-vessel angles, the spread of velocities limits the correlated signal interval, In addition, the experimental results demonstrate that accurate velocity estimation for low volume dow rates and particularly for large beam-vessel angles may involve detection of changes in the correlation magnitude. For low volume flow rates, the shape of the correlation surface can be affected by small regions of blood with a strong scattering intensity located near the initial region of interest.
引用
收藏
页码:416 / 428
页数:13
相关论文
共 16 条
[1]  
Ferrara K., Estimation of the Three dimensional velocity magnitude and beam-vessel angle,” submitted to, IEEE Trans. Ultrason., Ferroelect., and Freq. Cont
[2]  
Overbeck J.R., Beach K.W., Strandness D.E., Vector Doppler: Accurate measurement of blood velocity in two dimensions, Ultrasound in Medicine and Biology, 18, 1, pp. 19-31, (1992)
[3]  
Wang W., Yao L.A., Double beam Doppler ultrasound method for quantitative blood flow velocity measurement, Ultrasound in Medicine and Biologv, 8, pp. 421-425, (1982)
[4]  
Trahey G.E., Allison J.W., von Ramm O.T., Angle independent ultrasonic detection of blood flow, IEEE Trans. Biomedical Eng., 34, 12, pp. 964-967, (1987)
[5]  
Bohs L., Trahey G.E., A novel method for angle independent ultrasonic imaging of blood flow motion and tissue motion, IEEE Trans. Biomedical Eng., 38, pp. 280-286, (1991)
[6]  
Bascom P.A.J., Cobbold R.S.C., Roelofs B.H.M., Influence of spectral broadening on continuous wave doppler ultrasound spectra: A geometric approach, Ultrasound in Medicine and Biology, 12, 5, pp. 387-395, (1986)
[7]  
Douville Y., Johnston K.W., Kassam M., Determination of the hemodynamic factors which influence the carotid doppler spectral broadening, Ultrasound in Medicine and Biology, 11, 3, pp. 415-423, (1985)
[8]  
Gill R.W., Accuracy calculations for ultrasonic pulsed doppler blood flow measurements, Australasian Phys. Eng. Sci. in Med., 5, pp. 51-57, (1981)
[9]  
Gill R.W., Measurement of blood flow by ultrasound: Accuracy and sources of error, Ultrasound in Medicine and Biology, 11, 4, pp. 625-641, (1985)
[10]  
Newhouse V.L., Bendick P.J., Varner L.W., Analysis of transit time effects on Doppler flow measurements, IEEE Trans. Biomedical Eng., 23, 5, pp. 381-387, (1976)