BIOENERGETIC COMPARISON OF A NEW ENERGY-STORING FOOT AND SACH FOOT IN TRAUMATIC BELOW-KNEE VASCULAR AMPUTATIONS

被引:60
作者
CASILLAS, JM
DULIEU, V
COHEN, M
MARCER, I
DIDIER, JP
机构
[1] Service de rééducation Fonctionnelle, Centre Hospitalier Universitaire de Dijon, Cedex
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 1995年 / 76卷 / 01期
关键词
D O I
10.1016/S0003-9993(95)80040-9
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
In this study, the metabolic performances of a new energy-storing foot (Proteor) and of the solid-ankle cushion heel (SACH) are compared. Twelve patients with traumatic below-knee amputations (mean age: 50.0 +/- 19.9 years) and 12 patients with vascular below-knee amputations (mean age: 73 +/- 7 years) were studied. Oxygen uptake (VO2) was measured in all the subjects on a walkway at a self-selected velocity; only the subjects with traumatic amputation were tested on a level treadmill (progressive speed: 2.4-4 and 6 km/h), and then in two randomized trials: incline (+5%) and decline walking treadmill test at 4 km/h. Vascular explorations were done in the vascular patients: distal pressure measurements, pulse plethysmography, transcutaneous oxygen tension. Free walking was improved in subjects with traumatic amputation using the energy-storing foot (+6%), with a better bioenergetic efficiency (0.24 +/- 0.4mL/kg.m vs 0.22 +/- 0.04mL/kg.m). However, in subjects with vascular amputation, this foot did not produce an increased free velocity nor an improved energy cost. During the level treadmill test, the traumatic amputee subjects showed a decrease of energy expenditure with the new prosthetic foot, more significant at sufficient speed (4 km/h): 17.00 +/- 3.42 vs 14.67 +/- 2.05 mL/kg/min (p <.05). The same effect is shown during the incline (19.31 +/- 2.80 vs 16.79 +/- 2.32mL/kg/min-p <.02) and decline walking tests (14.13 +/- 3.64 vs 11.81 +/- 1.54mL/kg/min-p <.02). There is no significant difference in cardiocirculatory effects between the two types of prosthetic foot. Despite a lower velocity, the subjects with vascular amputation exceed 70% of the maximal heart rate, with the cardiocirculatory factor being the main cause of walking restriction. The energy-storing foot should be reserved for active and fast walkers, whereas the SACH foot seems more suitable for elderly patients with amputation with a slow walk. (C) 1995 by the American Congress of Rehabilitation Medicine and the American Academy of Physical Medicine and Rehabilitation
引用
收藏
页码:39 / 44
页数:6
相关论文
共 27 条
[1]  
[Anonymous], 1986, TXB WORK PHYSL
[2]  
BARD G, 1959, Arch Phys Med Rehabil, V40, P415
[3]   BIOMECHANICAL COMPARISON OF THE ENERGY-STORING CAPABILITIES OF SACH AND CARBON COPY II PROSTHETIC FEET DURING THE STANCE PHASE OF GAIT IN A PERSON WITH BELOW-KNEE AMPUTATION [J].
BARR, AE ;
SIEGEL, KL ;
DANOFF, JV ;
MCGARVEY, CL ;
TOMASKO, A ;
SABLE, I ;
STANHOPE, SJ .
PHYSICAL THERAPY, 1992, 72 (05) :344-354
[4]  
BARTH DG, 1989, J PROSTHET ORTHOT, V2, P63
[5]   THE USE OF TRANS-CUTANEOUS OXYGEN-TENSION MEASUREMENTS IN THE DIAGNOSIS OF PERIPHERAL VASCULAR INSUFFICIENCY [J].
BYRNE, P ;
PROVAN, JL ;
AMELI, FM ;
JONES, DP .
ANNALS OF SURGERY, 1984, 200 (02) :159-165
[6]   TRANSCUTANEOUS OXYGEN-PRESSURE - AN EFFECTIVE MEASURE FOR PROSTHESIS FITTING ON BELOW-KNEE AMPUTATIONS [J].
CASILLAS, JM ;
MICHEL, C ;
AURELLE, B ;
BECKER, F ;
MARCER, I ;
SCHULTZ, S ;
DIDIER, JP .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1993, 72 (01) :29-32
[7]   INSIGHTS INTO AMPUTEE RUNNING - A MUSCLE WORK ANALYSIS [J].
CZERNIECKI, JM ;
GITTER, A .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1992, 71 (04) :209-218
[8]   JOINT MOMENT AND MUSCLE POWER OUTPUT CHARACTERISTICS OF BELOW KNEE AMPUTEES DURING RUNNING - THE INFLUENCE OF ENERGY STORING PROSTHETIC FEET [J].
CZERNIECKI, JM ;
GITTER, A ;
MUNRO, C .
JOURNAL OF BIOMECHANICS, 1991, 24 (01) :63-75
[9]  
EHARA Y, 1993, ARCH PHYS MED REHAB, V74, P68
[10]  
FISHER SV, 1978, ARCH PHYS MED REHAB, V59, P124