NONINVASIVE ASSESSMENT OF CARDIAC-OUTPUT IN CHILDREN USING IMPEDANCE CARDIOGRAPHY

被引:48
作者
BRADEN, DS
LEATHERBURY, L
TREIBER, FA
STRONG, WB
机构
[1] Section of Cardiology, Medical College of Georgia, Augusta, Ga
关键词
D O I
10.1016/0002-8703(90)90132-H
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study evaluated the effect of intracardiac shungting on the accuracy of thoracic bioimpedance-derived cardiac output determinations. Twenty-six patients, ranging in age from 3 months to 17 years, underwent cardiac catheterization during which simultaneous Fick and impedance measurements of cardiac output were obtained. The subjects were divided into three groups: 10 children with no intracardiac shunts, nine children with predominant left-to-right intracardiac shunts, and seven children with predominant right-to-left intracardiac shunts. Positive correlations between impedance and Fick-derived cardiac output determinations were obtained in the non-shunt group (r = 0.84), with lower correlations in the left-to-right shunt group (r = 0.70). In the right-to-left shunt group, the impedance derived cardiac output correlated with Fick pulmonary flow (r = 0.82), but the variability was unacceptably large. Although further study is needed, impedance cardiography appears to have validity as a methodology in pediatric critical care and cardiovascular health research. © 1990.
引用
收藏
页码:1166 / 1172
页数:7
相关论文
共 24 条
[1]   RACIAL-DIFFERENCES IN STRESS-INDUCED CARDIOVASCULAR REACTIVITY AND HYPERTENSION - CURRENT STATUS AND SUBSTANTIVE ISSUES [J].
ANDERSON, NB .
PSYCHOLOGICAL BULLETIN, 1989, 105 (01) :89-105
[2]   COMPARISON OF MEASUREMENTS OF CARDIAC-OUTPUT BY BIOIMPEDANCE AND THERMODILUTION IN SEVERELY ILL SURGICAL PATIENTS [J].
APPEL, PL ;
KRAM, HB ;
MACKABEE, J ;
FLEMING, AW ;
SHOEMAKER, WC .
CRITICAL CARE MEDICINE, 1986, 14 (11) :933-935
[3]   CONTINUOUS NONINVASIVE REAL-TIME MONITORING OF STROKE VOLUME AND CARDIAC-OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :898-901
[4]   CARDIAC-OUTPUT IN NEONATAL-PERIOD USING IMPEDANCE CARDIOGRAPHY [J].
COSTELOE, K ;
STOCKS, J ;
GODFREY, S ;
MOHAPATRA, SN ;
HILL, DW .
PEDIATRIC RESEARCH, 1977, 11 (12) :1171-1177
[5]   IMPEDANCE CARDIOGRAPHIC ASSESSMENT OF SYMPTOMATIC PATENT DUCTUS-ARTERIOSUS [J].
COTTON, RB ;
LINDSTROM, DP ;
OLSSON, T ;
RIHA, M ;
GRAHAM, TP ;
SELSTAM, U ;
CATTERTON, WZ .
JOURNAL OF PEDIATRICS, 1980, 96 (04) :711-715
[6]   MEASUREMENT OF CARDIAC-OUTPUT BY ELECTRICAL IMPEDANCE AT REST AND DURING EXERCISE [J].
DENNISTON, JC ;
MAHER, JT ;
REEVES, JT ;
CRUZ, JC ;
CYMERMAN, A ;
GROVER, RF .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (01) :91-95
[7]   COMPARISON OF TRANS-THORACIC ELECTRICAL-IMPEDANCE AND THERMODILUTION METHODS FOR MEASURING CARDIAC-OUTPUT [J].
DONOVAN, KD ;
DOBB, GJ ;
WOODS, WPD ;
HOCKINGS, BE .
CRITICAL CARE MEDICINE, 1986, 14 (12) :1038-1044
[8]   IMPEDANCE CARDIOGRAMS RELIABLY ESTIMATE BEAT-BY-BEAT CHANGES OF LEFT-VENTRICULAR STROKE VOLUME IN HUMANS [J].
EBERT, TJ ;
ECKBERG, DL ;
VETROVEC, GM ;
COWLEY, MJ .
CARDIOVASCULAR RESEARCH, 1984, 18 (06) :354-360
[9]  
GASTFRIEND RJ, 1986, AM SURGEON, V52, P636
[10]  
GOTSHALL R W, 1987, American Journal of Physiology, V253, pH1298