CHANGE IN AMPLITUDE DISTRIBUTIONS OF DOPPLER SPECTROGRAMS RECORDED BELOW THE AORTIC-VALVE IN PATIENTS WITH A VALVULAR AORTIC-STENOSIS

被引:2
作者
CLOUTIER, G
LEMIRE, F
DURAND, LG
LATOUR, Y
JARRY, M
SOLIGNAC, A
LANGLOIS, YE
机构
[1] INST RECH CLIN MONTREAL,BIOMED ENGN LAB,MONTREAL H2W 1R7,QUEBEC,CANADA
[2] UNIV MONTREAL,ECOLE POLYTECH,INST GENIE BIOMED,MONTREAL H3C 3J7,QUEBEC,CANADA
[3] UNIV MONTREAL,HOTEL DIEU MONTREAL HOSP,DIV CARDIOL,MONTREAL H3C 3J7,QUEBEC,CANADA
[4] UNIV MONTREAL,HOTEL DIEU MONTREAL HOSP,DIV CARDIOVASC SURG,MONTREAL H3C 3J7,QUEBEC,CANADA
关键词
DOPPLER ULTRASOUND SPECTRUM; AMPLITUDE DISTRIBUTIONS; ATTENUATION OF BACKSCATTERED ULTRASONIC SIGNALS; BLOOD FLOW EDDIES; LEFT VENTRICULAR OUTFLOW TRACT; PULSED-WAVE TRANSMISSION; AORTIC VALVE STENOSIS;
D O I
10.1016/0301-5629(91)90097-G
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Amplitude distributions of Doppler spectrograms were characterized in a group of 22 patients having no aortic pressure gradient and another group of 26 patients having a stenotic aortic valve. Specifically, for each patient, the ratios of the mean amplitude in three normalized frequency bands (low, middle and high) to the mean amplitude of the Doppler spectrogram computed in selected portions of the systolic period were considered. Pulsed-wave Doppler spectrograms were recorded by positioning the sample volume in the left ventricular outflow tract, approximately 1 cm below the aortic valve. Statistically significant differences were found between the middle (p = 0.041) and high (p = 0.028) frequency bands of Doppler signals recorded from the two groups of patients. The differences observed are believed to be attributed to blood flow eddies generated below the stenotic aortic heart valve and to changes in blood flow orientation.
引用
收藏
页码:667 / 678
页数:12
相关论文
共 43 条
[1]   THEORETICAL-STUDY OF THE SCATTERING OF ULTRASOUND FROM BLOOD [J].
ANGELSEN, BAJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (02) :61-67
[2]  
Atkinson P., 1982, DOPPLER ULTRASOUND I
[3]   EVALUATION OF AORTIC-STENOSIS BY CONTINUOUS WAVE DOPPLER ULTRASOUND [J].
BERGER, M ;
BERDOFF, RL ;
GALLERSTEIN, PE ;
GOLDBERG, E .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (01) :150-156
[4]   ULTRASONIC ENERGY BACKSCATTERED FROM BLOOD - EXPERIMENTAL-DETERMINATION OF VARIATION OF SOUND ENERGY WITH HEMATOCRIT [J].
BORDERS, SE ;
FRONEK, A ;
KEMPER, WS ;
FRANKLIN, D .
ANNALS OF BIOMEDICAL ENGINEERING, 1978, 6 (02) :83-92
[5]  
CARO CG, 1978, MECHANICS CIRCULATIO
[6]   COMPUTER EVALUATION OF DOPPLER SPECTRAL ENVELOPE AREA IN PATIENTS HAVING A VALVULAR AORTIC-STENOSIS [J].
CLOUTIER, G ;
LEMIRE, F ;
DURAND, LG ;
LATOUR, Y ;
LANGLOIS, YE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (03) :247-260
[7]  
CLOUTIER G, 1990, 12TH P IEEE ENG MED, P560
[8]   CONTINUOUS-WAVE DOPPLER ECHOCARDIOGRAPHIC ASSESSMENT OF SEVERITY OF CALCIFIC AORTIC-STENOSIS - A SIMULTANEOUS DOPPLER-CATHETER CORRELATIVE STUDY IN 100 ADULT PATIENTS [J].
CURRIE, PJ ;
SEWARD, JB ;
REEDER, GS ;
VLIETSTRA, RE ;
BRESNAHAN, DR ;
BRESNAHAN, JF ;
SMITH, HC ;
HAGLER, DJ ;
TAJIK, AJ .
CIRCULATION, 1985, 71 (06) :1162-1169
[9]  
DANIELSEN R, 1988, BRIT HEART J, V59, P551
[10]   PULSED DOPPLER ACCURACY ASSESSMENT DUE TO FREQUENCY-DEPENDENT ATTENUATION AND RAYLEIGH-SCATTERING ERROR SOURCES [J].
EMBREE, PM ;
OBRIEN, WD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (03) :322-326