CLINICAL, IMMUNOLOGICAL AND BACTERIOLOGICAL EVALUATION OF ADVERSE REACTIONS TO SKIN-PENETRATING TITANIUM IMPLANTS IN THE HEAD AND NECK REGION

被引:72
作者
HOLGERS, KM
ROUPE, G
TJELLSTROM, A
BJURSTEN, LM
机构
[1] GOTHENBURG UNIV,SAHLGRENS HOSP,DEPT DERMATOL,S-41345 GOTHENBURG,SWEDEN
[2] GOTHENBURG UNIV,SAHLGRENS HOSP,DEPT EAR NOSE & THROAT,S-41345 GOTHENBURG,SWEDEN
[3] UNIV LUND,MALMO GEN HOSP,DEPT EXPTL RES,S-21401 MALMO,SWEDEN
关键词
SKIN-PENETRATING TITANIUM IMPLANTS; ADVERSE REACTIONS; BACTERIAL INFECTION; STAPHYLOCOCCUS-AUREUS; ANTIBIOTIC TREATMENT; FLUCLOXACILLIN;
D O I
10.1111/j.1600-0536.1992.tb05189.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Between 1977 and October 1989, 445 patients have been treated with bone-anchored skin-penetrating titanium implants for anchorage of facial prostheses or bone-conducting hearing aids. at the Ear, Nose and Throat Department at Sahlgren's Hospital in Gothenburg. The majority of patients had no adverse skin reactions, while a few patients were responsible for the majority of the adverse reactions. The aim of our study was to analyse differences between these groups. We started a clinical study on 9 patients with a clinical history of adverse skin reactions around the titanium implants and 9 patients without adverse skin reactions were used as controls. None of the patients had delayed hypersensitivity to titanium. Microbiological analyses showed that when there was clinical irritation, Staphylococcus aureus could be isolated.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 16 条
[1]   THE SKIN IMMUNE-SYSTEM (SIS) - DISTRIBUTION AND IMMUNOPHENOTYPE OF LYMPHOCYTE SUBPOPULATIONS IN NORMAL HUMAN-SKIN [J].
BOS, JD ;
ZONNEVELD, I ;
DAS, PK ;
KRIEG, SR ;
VANDERLOOS, CM ;
KAPSENBERG, ML .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1987, 88 (05) :569-573
[2]   NICKEL SENSITIZATION FROM EAR PIERCING [J].
BOSS, A ;
MENNE, T .
CONTACT DERMATITIS, 1982, 8 (03) :211-213
[3]  
BRANEMARK P, 1977, SCAND J PLAST RE S16, V11
[4]  
FREW AJ, 1988, J IMMUNOL, V141, P4158
[5]  
GAUL E, 1975, JAMA-J AM MED ASSOC, V200, P176
[6]  
Holgers K M, 1989, J Invest Surg, V2, P7, DOI 10.3109/08941938909016500
[7]  
Holgers K M, 1987, Int J Oral Maxillofac Implants, V2, P35
[8]  
HOLGERS KM, 1988, AM J OTOL, V9, P56
[9]   PACEMAKER CONTACT SENSITIVITY [J].
PETERS, MS ;
SCHROETER, AL ;
VANHALE, HM ;
BROADBENT, JC .
CONTACT DERMATITIS, 1984, 11 (04) :214-218
[10]  
PIRILA V, 1975, CONTACT DERMATITIS, V1, P68