AN ELECTROLUMINESCENCE OPTICAL SENSOR SYSTEM BASED ON TIO2 FILM ELECTRODES FOR CONTINUOUS MEASUREMENT OF H2O2 CONCENTRATION IN SOLUTION

被引:11
作者
POZNYAK, SK
KULAK, AI
机构
[1] Institute of Physico-Chemical Problems, Belarusian State University, Minsk
关键词
ELECTROLUMINESCENCE OPTICAL SENSOR SYSTEM; ELECTROLUMINESCENCE SEMICONDUCTOR OPTRODES; HYDROGEN PEROXIDE SENSOR; TITANIUM DIOXIDE;
D O I
10.1016/0925-4005(94)87006-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electroluminescence semiconductor optrodes (ELSOs), electrochemical optical sensor systems based on recording the electroluminescence response from semiconductor electrodes, have been proposed for the detection and analysis of chemical species in solution. The possibility of developing an ELSO sensitive to hydrogen peroxide in alkaline solutions has been demonstrated using TiO2 film electrodes. The electroluminescence from this optrode arises under conditions of negative polarization as a result of hole injection in the TiO2 from high-energy OH radicals formed by the electroreduction of H2O2 on the electrode surface. The integrated electroluminescence response as well as a value of the electroluminescence intensity measured immediately after applying the pulsed polarization change linearly on a logarithmic scale when the H2O2 concentration changes in the range 10(-3)-5 x 10(-1) mol 1(-1).
引用
收藏
页码:97 / 100
页数:4
相关论文
共 18 条
[1]   KOHLRABI-BASED AMPEROMETRIC BIOSENSOR FOR HYDROGEN-PEROXIDE MEASUREMENT [J].
CHEN, L ;
LIN, MS ;
HARA, M ;
RECHNITZ, GA .
ANALYTICAL LETTERS, 1991, 24 (01) :1-14
[2]   CHEMICALLY IMMOBILIZED ENZYME ELECTRODES FOR HYDROGEN-PEROXIDE DETERMINATION [J].
COSGROVE, M ;
MOODY, GJ ;
THOMAS, JDR .
ANALYST, 1988, 113 (12) :1811-1815
[3]   METAL-OXIDE CATALYST MEMBRANE ELECTRODES FOR THE DETERMINATION OF HYDROGEN-PEROXIDE [J].
COSGROVE, M ;
MOODY, GJ ;
THOMAS, JDR .
ANALYST, 1989, 114 (12) :1627-1632
[4]  
FREEMAN T M, 1978, Analytical Chemistry, V50, P1242, DOI 10.1021/ac50031a012
[5]  
Guthrie A. J., 1987, Transactions of the Institute of Measurement and Control, V9, P71, DOI 10.1177/014233128700900203
[6]   CARRIERS FOR CHEMICAL SENSORS - DESIGN-FEATURES OF OPTICAL SENSORS (OPTODES) BASED ON SELECTIVE CHROMOIONOPHORES [J].
MORF, WE ;
SEILER, K ;
LEHMANN, B ;
BEHRINGER, C ;
HARTMAN, K ;
SIMON, W .
PURE AND APPLIED CHEMISTRY, 1989, 61 (09) :1613-1618
[7]   LUMINESCENCE SPECTRA FROM N-TIO2 AND N-SRTIO3 SEMICONDUCTOR ELECTRODES AND THOSE DOPED WITH TRANSITION-METAL OXIDES AS RELATED WITH INTERMEDIATES OF THE PHOTOOXIDATION REACTION OF WATER [J].
NAKATO, Y ;
OGAWA, H ;
MORITA, K ;
TSUBOMURA, H .
JOURNAL OF PHYSICAL CHEMISTRY, 1986, 90 (23) :6210-6216
[8]   PHOTOLUMINESCENCE AND ELECTRO-LUMINESCENCE SPECTRA FROM AN N-TIO2 SEMICONDUCTOR ELECTRODE AS RELATED TO THE INTERMEDIATES OF THE PHOTO-OXIDATION REACTION OF WATER [J].
NAKATO, Y ;
TSUMURA, A ;
TSUBOMURA, H .
JOURNAL OF PHYSICAL CHEMISTRY, 1983, 87 (13) :2402-2405
[9]   SEMICONDUCTOR ELECTRODES .14. ELECTROCHEMISTRY AND ELECTROLUMINESCENCE AT N-TYPE TIO2 IN AQUEOUS-SOLUTIONS [J].
NOUFI, RN ;
KOHL, PA ;
FRANK, SN ;
BARD, AJ .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1978, 125 (02) :246-252
[10]   ELECTROLUMINESCENCE AT SEMICONDUCTOR ELECTRODES CAUSED BY HOLE INJECTION FROM ELECTROLYTES [J].
PETTINGER, B ;
SCHOPPEL, HR ;
GERISCHER, H .
BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1976, 80 (09) :849-855