COMPARATIVE EFFICACY OF TOPICAL HEMOSTATIC AGENTS IN A RAT-KIDNEY MODEL

被引:43
作者
RACCUIA, JS [1 ]
SIMONIAN, G [1 ]
DARDIK, M [1 ]
HALLAC, D [1 ]
RACCUIA, SV [1 ]
STAHL, R [1 ]
DARDIK, H [1 ]
机构
[1] ENGLEWOOD HOSP,DEPT SURG,SURG RES LAB,ENGLEWOOD,NJ 07631
关键词
D O I
10.1016/0002-9610(92)90108-4
中图分类号
R61 [外科手术学];
学科分类号
摘要
The efficacies of four topical hemostatic agents were compared in a rat model employing a standardized renal injury. The materials used to effect hemostasis were oxidized cellulose, microfibrillar collagen powder, positively charged modified collagen, and single donor heterologous fibrin glue. Animals that were treated only with surgical gauze served as controls. Hemostasis was achieved by application of one of the topical hemostatic agents plus moderate digital pressure. The time necessary to achieve complete hemostasis was recorded for each animal. Control animals bled profusely and suffered an increased postoperative mortality rate compared with the experimental animals. Microscopic studies demonstrated progressive healing of the injuries with varying degrees of inflammation and scar formation. Fibrin glue was by far the most effective agent in controlling hemostasis. The collagen materials, though effective, required a longer time to control bleeding and did not differ statistically in their activity from one another.
引用
收藏
页码:234 / 238
页数:5
相关论文
共 24 条
[1]  
ABBOTT WM, 1975, SURGERY, V78, P723
[2]   COLLOIDAL MACROMOLECULAR PHENOMENA .2. NOVEL MICROCRYSTALS OF POLYMERS [J].
BATTISTA, OA ;
ERDI, NZ ;
FERRARO, CF ;
KARASINS.FJ .
JOURNAL OF APPLIED POLYMER SCIENCE, 1967, 11 (04) :481-&
[3]   DER EINFLUSS DES FIBRINSTABILISIERENDEN FAKTORS (FSF) AUF FUNKTION UND MORPHOLOGIE VON FIBROBLASTEN INVITRO [J].
BECK, E ;
DUCKERT, F ;
VOGEL, A ;
ERNST, M .
ZEITSCHRIFT FUR ZELLFORSCHUNG UND MIKROSKOPISCHE ANATOMIE, 1962, 57 (03) :327-346
[4]   A STANDARDIZED ANIMAL-MODEL FOR EVALUATION OF HEMOSTATIC EFFECTIVENESS OF VARIOUS MATERIALS [J].
CHVAPIL, M ;
OWEN, JA ;
DEYOUNG, DW .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1983, 23 (12) :1042-1047
[5]   EVALUATION OF HEMOSTATIC AGENTS IN EXPERIMENTAL SPLENIC LACERATIONS [J].
COLN, D ;
HORTON, J ;
OGDEN, ME ;
BUJA, LM .
AMERICAN JOURNAL OF SURGERY, 1983, 145 (02) :256-259
[6]  
CORRELL JT, 1945, SURG GYNECOL OBSTET, V81, P585
[7]   EVALUATION OF HEMOSTASIS WITH GOLD FOIL [J].
DARDIK, H ;
ALTMAN, A ;
PODOLSKY, S ;
DARDIK, I .
AMERICAN JOURNAL OF SURGERY, 1968, 116 (03) :419-&
[8]  
DINEEN P, 1976, SURG GYNECOL OBSTET, V142, P481
[9]  
DRESDALE A, 1985, SURGERY, V97, P750
[10]   HEMOSTATIC EFFECTIVENESS OF FIBRIN GLUE DERIVED FROM SINGLE-DONOR FRESH-FROZEN PLASMA [J].
DRESDALE, A ;
BOWMAN, FO ;
MALM, JR ;
REEMTSMA, K ;
SMITH, CR ;
SPOTNITZ, HM ;
ROSE, EA .
ANNALS OF THORACIC SURGERY, 1985, 40 (04) :385-387