THE USE OF MEASURED ACOUSTIC SPEED DISTRIBUTIONS IN REFLECTION ULTRASOUND CT

被引:11
作者
JAGO, JR
WHITTINGHAM, TA
机构
[1] Reg. Med. Phys. Dept., Newcastle General Hospital, Newcastle upon Tyne
关键词
D O I
10.1088/0031-9155/37/11/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Brief details have been given of an ultrasound CT system based on linear arrays which can be used to generate both reflection UCT images and acoustic speed images of a suitable target section. The acoustic speed images have been shown to be of sufficient quality to provide high registration accuracy in the equivalent reflection images. The quality of the reflection images so produced is felt to be higher than has so far been achieved by any previous published work in the field of ultrasound CT. These results offer promise for the imaging of suitable in vivo targets such as the adult breast, neck and scrotum and the neonate.
引用
收藏
页码:2139 / 2142
页数:4
相关论文
共 7 条
[2]  
FRIEDRICH M, 1982, EUR J RADIOL, V2, P78
[3]  
HILLER D, 1982, ACOUST IMAGING, V12, P553
[4]   EXPERIMENTAL STUDIES IN TRANSMISSION ULTRASOUND COMPUTED-TOMOGRAPHY [J].
JAGO, JR ;
WHITTINGHAM, TA .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (11) :1515-1527
[5]   TOMOGRAPHIC IMAGING OF ULTRASONIC REFLECTIVITY WITH CORRECTION FOR ACOUSTIC SPEED VARIATIONS [J].
KIM, JH ;
PARK, SB ;
JOHNSON, SA .
ULTRASONIC IMAGING, 1984, 6 (03) :304-312
[6]  
MADERLECHNER G, 1980, ACOUST IMAGING, V10, P415
[7]  
Wade G., 1978, ACOUST IMAGING, V8, P565