HIGH-ENERGY HIGH-RESOLUTION MONOCHROMATIC X-RAY COMPUTED-TOMOGRAPHY USING THE PHOTON FACTORY VERTICAL WIGGLER BEAMLINE

被引:10
作者
NAGATA, Y [1 ]
YAMAJI, H [1 ]
HAYASHI, K [1 ]
KAWASHIMA, K [1 ]
HYODO, K [1 ]
KAWATA, H [1 ]
ANDO, M [1 ]
机构
[1] NATL LAB HIGH ENERGY PHYS,PHOTON FACTORY,TSUKUBA,IBARAKI 305,JAPAN
关键词
D O I
10.1063/1.1142668
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have developed a high resolution monochromatic x-ray computed tomography system using synchrotron radiation in the energy range up to 50 keV. The system was installed in a vertical wiggler beamline (BL14C) at the Photon Factory of the National Laboratory for High Energy Physics, and consists of a double-crystal monochromator employing asymmetric Bragg reflections, a photodiode array detector with a phosphor screen, and a microcomputer for control. Computed tomography (CT) images with a pixel size of 6 to 8-mu-m and with a slice width ranging from 20 to 100-mu-m were obtained. An image subtraction technique for CT images above and below the x-ray absorption edge of iodine was also evaluated for liquid-containing glass capillaries. Since the CT value (pixel weighting) is linearly proportional to the concentration, the system can quantitatively evaluate the concentration distribution of iodine. These results indicate that the system is very useful for nondestructively evaluating fine structures and their constituent elements.
引用
收藏
页码:615 / 618
页数:4
相关论文
共 12 条
[1]   DESIGN OF BEAMLINE 14 FOR THE PF VERTICAL WIGGLER AND ITS OPERATION [J].
ANDO, M ;
SATOW, Y ;
KAWATA, H ;
ISHIKAWA, T ;
SPIEKER, P ;
SUZUKI, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :144-148
[2]  
Brase JM, 1988, MRS BULL, V13, P13
[3]   A SYSTEM FOR DUAL ENERGY MICROTOMOGRAPHY OF BONES [J].
ENGELKE, K ;
LOHMANN, M ;
DIX, WR ;
GRAEFF, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 274 (1-2) :380-389
[4]   3-DIMENSIONAL X-RAY MICROTOMOGRAPHY [J].
FLANNERY, BP ;
DECKMAN, HW ;
ROBERGE, WG ;
DAMICO, KL .
SCIENCE, 1987, 237 (4821) :1439-1444
[5]   OPTIMUM ENERGIES FOR X-RAY TRANSMISSION TOMOGRAPHY OF SMALL SAMPLES - APPLICATIONS OF SYNCHROTRON RADIATION TO COMPUTERIZED-TOMOGRAPHY .1. [J].
GRODZINS, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 206 (03) :541-545
[6]   CRITICAL ABSORPTION TOMOGRAPHY OF SMALL SAMPLES - PROPOSED APPLICATIONS OF SYNCHROTRON RADIATION TO COMPUTERIZED-TOMOGRAPHY .2. [J].
GRODZINS, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 206 (03) :547-552
[7]   HIGH-RESOLUTION MONOCHROMATIC TOMOGRAPHY WITH X-RAY SENSING PICKUP TUBE [J].
HIRANO, T ;
USAMI, K ;
SAKAMOTO, K .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :2482-2485
[8]  
KITAMURA H, 1990, INSERTION DEVICE HDB, P105
[9]  
NAGATA Y, 1990, 8 PHOT FACT ACT REP, P293
[10]  
NAGATA Y, 1991, IN PRESS 5TH P INT S