ENDOSCOPE DECONTAMINATION - AUTOMATED VS MANUAL

被引:37
作者
BRADLEY, CR
BABB, JR
机构
[1] Hospital Infection Research Laboratory, City Hospital NHS Trust, Birmingham, B18 7QH, Dudley Road
关键词
DISINFECTION; ENDOSCOPES; AUTOMATION;
D O I
10.1016/0195-6701(95)90060-8
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Automated endoscope washer disinfectors are widely used for the decontamination of flexible endoscopes. They are more effective than manual techniques and reduce the likelihood of skin contact with irritant disinfectants. Suitable machines are those which effectively clean, disinfect and rinse all channels and external surfaces without damaging the instrument. If glutaraldehyde is used, fumes should be removed or contained to protect endoscopy and processing staff. Machines should also be equipped with a self-disinfect facility and the rinse water should be of a suitable microbiological quality for the instruments processed, i.e. bacteria-free (sterile or filtered) water should be used for bronchoscopes and all invasive endoscope. The choice of machine and cycle will depend on the following: whether a mobile or fixed unit is required; the type of disinfectant used; instrument throughput; and whether or not it is necessary to process more than one endoscope at a time. Purchasers are advised to request independent test reports which substantiate manufacturers' claims.
引用
收藏
页码:537 / 542
页数:6
相关论文
共 15 条
[1]  
ALVARADO CJ, 1991, AM J MED S3B, V91, P2725
[2]  
AYLIFFE GAJ, 1993, INFECTION ENDOSCOPY, V3, P411
[3]  
Babb J R, 1992, J Hosp Infect, V20, P51, DOI 10.1016/0195-6701(92)90061-P
[4]   DISINFECTION AND STERILIZATION OF ENDOSCOPES [J].
BABB, JR .
CURRENT OPINION IN INFECTIOUS DISEASES, 1993, 6 (04) :532-537
[5]   THE MECHANICS OF ENDOSCOPE DISINFECTION [J].
BABB, JR ;
BRADLEY, CR .
JOURNAL OF HOSPITAL INFECTION, 1991, 18 :130-135
[6]  
BABB JR, 1993, CENTRAL SERVICE, V4, P227
[7]  
Bradley C, 1994, Nurs Times, V90, P70
[8]   MYCOBACTERIAL CONTAMINATION OF FIBEROPTIC BRONCHOSCOPES [J].
BROWN, NM ;
HELLYAR, EA ;
HARVEY, JE ;
REEVES, DS .
THORAX, 1993, 48 (12) :1283-1285
[9]   INVESTIGATION OF AN OUTBREAK OF BLOODY DIARRHEA - ASSOCIATION WITH ENDOSCOPIC CLEANING SOLUTION AND DEMONSTRATION OF LESIONS IN AN ANIMAL-MODEL [J].
DURANTE, L ;
ZULTY, JC ;
ISRAEL, E ;
POWERS, PJ ;
RUSSELL, RG ;
QIZILBASH, AH ;
MORRIS, JG .
AMERICAN JOURNAL OF MEDICINE, 1992, 92 (05) :476-480
[10]   MYCOBACTERIUM-CHELONEI ISOLATION FROM BRONCHOALVEOLAR LAVAGE FLUID AND ITS PRACTICAL IMPLICATIONS [J].
NYE, K ;
CHADHA, DK ;
HODGKIN, P ;
BRADLEY, C ;
HANCOX, J ;
WISE, R .
JOURNAL OF HOSPITAL INFECTION, 1990, 16 (03) :257-261