Colour flow duplex scanning: An accurate, non-invasive technique for preoperative evaluation of the vascular supply of the rectus abdominis myocutaneous flap

被引:11
作者
Pacifici, A
Tinti, A
Flamini, FO
Cordellini, M
Trapassi, S
Dominici, C
机构
[1] UNIV PERUGIA,MONTELUCE HOSP,DIV PLAST & RECONSTRUCT SURG,I-06100 PERUGIA,ITALY
[2] SAN MATTEO INFERMI HOSP,DIV ANGIOL,SPOLETO,ITALY
来源
SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY | 1995年 / 29卷 / 04期
关键词
echo colour Doppler; colour flow duplex scanning; rectus abdominis myocutaneous flap; epigastric arteries; breast reconstruction; penile reconstruction;
D O I
10.3109/02844319509008966
中图分类号
R61 [外科手术学];
学科分类号
摘要
Forty patients were examined with colour Doppler to study the vascularization of rectus abdominis myocutaneous flaps before operations. The accuracy of this non-invasive ultrasound technique allowed us to describe the characteristics of the blood flow, including volume and velocity, diameter of vessels and their transverse section area within the epigastric arteries which supply the superior and inferior vascular pedicles of the flap. Vessels are drawn on the skin surface so that the flap can be more precisely and rapidly dissected. We are now using colour Doppler to assess variations in the diameter of vessels and in other variables of blood flow within the vascular pedicle of the transferred flap. These evaluations before and after operation are a great help to the reconstructive surgeon in the choice of operation and will lead to an appreciable reduction in postoperative morbidity.
引用
收藏
页码:319 / 324
页数:6
相关论文
共 13 条
[1]  
BORGATTI E, 1991, ECODUPLEX COLOR DOPP, P103
[2]  
BOSTWICK J, 1990, PLASTIC RECONSTRUCTI, P759
[3]   THE VASCULAR TERRITORIES OF THE SUPERIOR EPIGASTRIC AND THE DEEP INFERIOR EPIGASTRIC SYSTEMS [J].
BOYD, JB ;
TAYLOR, GI ;
CORLETT, R .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1984, 73 (01) :1-14
[4]  
CRAMER MM, 1993, J VASC TECHNOL, V17, P7
[5]   EPIGASTRIC ISLAND FLAP [J].
DREVER, JM .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1977, 59 (03) :343-346
[6]   TRANSACTION COST-ANALYSIS OF STRATEGY-STRUCTURE CHOICE [J].
JONES, GR ;
HILL, CWL .
STRATEGIC MANAGEMENT JOURNAL, 1988, 9 (02) :159-172
[7]  
MATHES SJ, 1992, CLIN APPLICATION MUS, V3, P719
[8]   TRAM FLAP SAFETY OPTIMIZED WITH INTRAOPERATIVE DOPPLER [J].
MICHELOW, BJ ;
HARTRAMPF, CR ;
BENNETT, GK .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1990, 86 (01) :143-146
[9]  
MOELLEKEN BRW, 1990, PERSPECT PLAST SURG, V4, P112
[10]  
PACIFICI A, 1992, RIV ITAL CHIR PLAST, V24, P337