3D PET USING A CONVENTIONAL MULTISLICE TOMOGRAPH WITHOUT SEPTA

被引:121
作者
CHERRY, SR
DAHLBOM, M
HOFFMAN, EJ
机构
[1] Division of Nuclear Medicine and Biophysics, University of California at Los Angeles School of Medicine, Los Angeles, CA, 90024-1721
关键词
EMISSION COMPUTED TOMOGRAPHY; 3-DIMENSIONAL; TECHNIQUES;
D O I
10.1097/00004728-199107000-00023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A conventional multislice positron emission tomography scanner was modified to operate without interplane septa to evaluate its performance in collecting and reconstructing data in a three-dimensional (3D) format, thereby significantly incrasing system sensitivity. A 3D filtered backprojection algorithm was implemented and tested, using both computer simulations and phantom measurements. No artifacts were apparent in the test images, although the algorithm was shown to lead to a 11% degradation in transaxial resolution in the outer planes. Following septa removal sensitivity was found to increase by a factor of 7 with an increase in scatter fraction from 16 to 41%. Axial resolution degraded from 6.9 to 7.7 mm full width at half maximum at the center of the field of view. The maximum count rate without septa was 2.4 x 10(5) cps, at a concentration of 0.4-mu-Ci/ml, compared with 1.3 x 10(5) cps at 1.5-mu-Ci/ml with septa. Brain studies were performed with volunteers using F-18-fluorodeoxyglucose, F-18-fluorodopa, and (H2O)-O-15 to compare noise-equivalent count rates and qualitatively assess image quality over a wide range of imaging conditions.
引用
收藏
页码:655 / 668
页数:14
相关论文
共 24 条
[1]   CORRECTION FOR SCATTERED RADIATION IN A RING DETECTOR POSITRON CAMERA BY INTEGRAL TRANSFORMATION OF THE PROJECTIONS [J].
BERGSTROM, M ;
ERIKSSON, L ;
BOHM, C ;
BLOMQVIST, G ;
LITTON, J .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (01) :42-50
[2]   FULLY 3-DIMENSIONAL POSITRON EMISSION TOMOGRAPHY [J].
COLSHER, JG .
PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (01) :103-115
[3]   AN EVALUATION OF A TWO-DIMENSIONAL ARRAY DETECTOR FOR HIGH-RESOLUTION PET [J].
DAHLBOM, M ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (04) :264-272
[4]   A STUDY OF THE POSSIBILITY OF USING MULTI-SLICE PET SYSTEMS FOR 3D IMAGING [J].
DAHLBOM, M ;
ERIKSSON, L ;
ROSENQVIST, G ;
BOHM, C .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1066-1071
[5]   IMPLEMENTATION OF 3-DIMENSIONAL IMAGE-RECONSTRUCTION FOR MULTIRING POSITRON TOMOGRAPHS [J].
DEFRISE, M ;
TOWNSEND, D ;
GEISSBUHLER, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) :1361-1372
[6]  
DIFFRIENT N, 1974, HUMANSCALE 1 2 3
[7]   DETECTOR, SHIELDING AND GEOMETRIC DESIGN FACTORS FOR A HIGH-RESOLUTION PET SYSTEM [J].
DIGBY, WM ;
DAHLBOM, M ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :664-670
[8]   A STUDY OF DATA LOSS AND MISPOSITIONING DUE TO PILEUP IN 2-D DETECTORS IN PET [J].
GERMANO, G ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :671-675
[9]  
GRAFTON ST, 1989, J CEREB BLOOD FLO S1, V9, pS404
[10]  
HOFFMAN E J, 1988, Journal of Nuclear Medicine, V29, P983