BLOOD CLEARANCE RATES OF ANGIOTENSIN-II AND ITS METABOLITES IN SHEEP - PRESENCE OF IMMUNOREACTIVE FRAGMENTS IN ARTERIAL BLOOD

被引:16
作者
FEI, DTW [1 ]
COGHLAN, JP [1 ]
FERNLEY, RT [1 ]
SCOGGINS, BA [1 ]
机构
[1] UNIV MELBOURNE, HOWARD FLOREY INST EXPTL PHYSIOL & MED, PARKVILLE 3052, VICTORIA, AUSTRALIA
关键词
D O I
10.1111/j.1440-1681.1979.tb00017.x
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
1. The blood clearance rates of exogenous (des‐1‐Asp)‐angiotensin II and (des‐1‐Asp‐2‐Arg)‐angiotensin II calculated from the arterial blood level during steady state infusion in conscious sodium‐replete sheep were found to be 125 litre/h (s.d. = 27, n= 18) and 188 litre/h (s.d. = 23, n= 18), respectively. These blood clearance rates were in the same order as values for angiotensin II previously reported. 2. Using descending paper chromatography, immunoreactive fragments of angiotensin II in arterial blood extracts were adequately separated from angiotensin II. Quantitative determination of angiotensin II by direct immunoassay on whole blood extract using recovery tracer to correct for losses during extraction were on the average 31% (n= 9) higher than those obtained after the same blood extract had been subjected to chromatographic separation. 3. The blood clearance rates of exogenous 1‐Asp‐5‐Ile‐angiotensin II calculated from infusion rate/blood angiotensin II concentration before and after chromatographic separation were significantly different, being 103 litre/h (s.d. = 16, n= 18) and 134 litre/h (s.d. = 25, n= 9), respectively (P < 0.001; t‐test, 16 d.f.). 4. Our data demonstrate the presence of immunoreactive fragments of angiotensin II in arterial blood of sheep during steady‐state infusion and indicate that direct immunoassay on arterial blood extracts without adequate separation may result in artificially higher values of angiotensin II in blood and consequently false value for its clearance rate. Copyright © 1979, Wiley Blackwell. All rights reserved
引用
收藏
页码:129 / 137
页数:9
相关论文
共 22 条
[1]  
BLAIRWEST JR, 1971, AM J PHYSIOL, V220, P1309
[2]  
BOYD GW, 1967, LANCET, V2, P1002
[3]   IMMUNOREACTIVE FRAGMENTS OF ANGIOTENSIN 2 IN BLOOD [J].
CAIN, MD ;
CATT, KJ ;
COGHLAN, JP .
NATURE, 1969, 223 (5206) :617-&
[4]   EVALUATION OF ANGIOTENSIN-II METABOLISM IN SHEEP BY RADIOIMMUNOASSAY [J].
CAIN, MD ;
CATT, KJ ;
COGHLAN, JP ;
BLAIRWES,JR .
ENDOCRINOLOGY, 1970, 86 (05) :955-+
[5]   MEASUREMENT OF ANGIOTENSIN-II IN BLOOD BY RADIOIMMUNOASSAY [J].
CAIN, MD ;
CATT, KJ ;
COGHLAN, JP .
CLINICA CHIMICA ACTA, 1972, 39 (01) :21-+
[6]   EFFECT OF CIRCULATING FRAGMENTS OF ANGIOTENSIN-11 ON RADIOIMMUNOASSAY IN ARTERIAL AND VENOUS BLOOD [J].
CAIN, MD ;
CATT, KJ ;
COGHLAN, JP .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1969, 29 (12) :1639-+
[7]   BLOOD-PRESSURE AND PLASMA ANGIOTENSIN-2 CONCENTRATION AFTER RENAL-ARTERY CONSTRICTION AND ANGIOTENSIN INFUSION IN DOG - [5-ISOLEUCINE]ANGIOTENSIN-2 AND ITS BREAKDOWN FRAGMENTS IN DOG BLOOD [J].
CARAVAGGI, AM ;
BIANCHI, G ;
BROWN, JJ ;
LEVER, AF ;
MORTON, JJ ;
POWELLJACKSON, JD ;
ROBERTSON, JIS ;
SEMPLE, PF .
CIRCULATION RESEARCH, 1976, 38 (04) :315-321
[8]   IMMUNOLOGICAL REACTIVITY OF PEPTIDES RELATED TO ANGIOTENSIN [J].
CATT, KJ ;
COGHLAN, JP ;
ROMBERG, B .
NATURE, 1967, 215 (5099) :395-&
[9]  
CATT KJ, 1967, LANCET, V2, P1005
[10]   IMMUNOCHEMICAL ANALYSIS OF RABBIT ANTIBODIES AGAINST ANGIOTENSIN 2 [J].
DIETRICH, FM .
IMMUNOCHEMISTRY, 1967, 4 (02) :65-&