TISSUE MAXIMUM RATIOS (AND OTHER PARAMETERS) OF SMALL CIRCULAR 4, 6, 10, 15 AND 24 MV X-RAY-BEAMS FOR RADIOSURGERY

被引:56
作者
SERAGO, CF
HOUDEK, PV
HARTMANN, GH
SAINI, DS
SERAGO, ME
KAYDEE, A
机构
[1] UNIV MIAMI,DEPT RADIAT ONCOL,MIAMI,FL 33152
[2] GERMAN CANC RES CTR,DEPT RADIOL DIAGNOST & THERAPY,W-6900 HEIDELBERG 1,GERMANY
[3] HOLMES REG MED CTR,DEPT RADIAT ONCOL,MELBOURNE,FL
关键词
D O I
10.1088/0031-9155/37/10/010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Small, circular, x-ray beams are commonly used for radiosurgery applications. Dosimetric characteristics of 4, 6, 10, 15 and 24 MV circular x-ray beams ranging in size from 10 to 40 mm are reported. These characteristics include the measurement of TMR, beam profiles and relative output factors. Measurements of these parameters were performed in a solid water phantom using film, a small diode, small parallel-plate and cylindrical ionization chambers and TLD. Comparison of relative dose measurements of small, circular beams performed using these detectors showed that the small diode, film and TLD results consistently agreed for circular beams as small as 10 mm diameter. Beam profiles were measured using film dosimetry. Comparison of TMR values of a 10 mm diameter beam measured using film and a small parallel-plate ionization chamber showed no significant differences. Tertiary collimators designed with tapered, divergence-matching holes, and straight-drilled holes have been used for radiosurgery applications. Measurement of beam penumbra produced with either of these types of tertiary collimators showed minimal differences between them.
引用
收藏
页码:1943 / 1956
页数:14
相关论文
共 11 条
[1]   DOSE MEASUREMENTS AND CALCULATIONS OF SMALL RADIATION-FIELDS FOR 9-MV X-RAYS [J].
ARCOVITO, G ;
PIERMATTEI, A ;
DABRAMO, G ;
BASSI, FA .
MEDICAL PHYSICS, 1985, 12 (06) :779-784
[2]  
BJARNGARD BE, 1990, MED PHYS, V17, P794, DOI 10.1118/1.596475
[3]   EXTERNAL STEREOTACTIC IRRADIATION BY LINEAR-ACCELERATOR [J].
COLOMBO, F ;
BENEDETTI, A ;
POZZA, F ;
AVANZO, RC ;
MARCHETTI, C ;
CHIEREGO, G ;
ZANARDO, A .
NEUROSURGERY, 1985, 16 (02) :154-160
[4]   ELECTRONIC EQUILIBRIUM AND TRANSITION STAGES [J].
DUTREIX, J ;
DUTREIX, A ;
TUBIANA, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1965, 10 (02) :177-&
[5]   CEREBRAL RADIATION SURGERY USING MOVING FIELD IRRADIATION AT A LINEAR-ACCELERATOR FACILITY [J].
HARTMANN, GH ;
SCHLEGEL, W ;
STURM, V ;
KOBER, B ;
PASTYR, O ;
LORENZ, WJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (06) :1185-1192
[6]  
HOUDEK PV, 1983, MED PHYS, V100, P333
[7]   MONTE-CARLO AND CONVOLUTION DOSIMETRY FOR STEREOTAXIC RADIOSURGERY [J].
KUBSAD, SS ;
MACKIE, TR ;
GEHRING, MA ;
MISISCO, DJ ;
PALIWAL, BR ;
MEHTA, MP ;
KINSELLA, TJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (04) :1027-1035
[8]   A SYSTEM FOR STEREOTACTIC RADIOSURGERY WITH A LINEAR-ACCELERATOR [J].
LUTZ, W ;
WINSTON, KR ;
MALEKI, N .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (02) :373-381
[9]   DYNAMIC STEREOTACTIC RADIOSURGERY [J].
PODGORSAK, EB ;
OLIVIER, A ;
PLA, M ;
LEFEBVRE, PY ;
HAZEL, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (01) :115-126
[10]   MEASUREMENTS OF DOSE DISTRIBUTIONS IN SMALL BEAMS OF 6 MV X-RAYS [J].
RICE, RK ;
HANSEN, JL ;
SVENSSON, GK ;
SIDDON, RL .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (09) :1087-1099