INITIAL EXPERIENCE WITH TRANSVENOUS IMPLANTABLE CARDIOVERTER DEFIBRILLATOR LEAD SYSTEMS - OPERATIVE MORBIDITY AND MORTALITY

被引:31
作者
FRAME, R
BRODMAN, R
GROSS, J
HOLLINGER, I
FISHER, JD
KIM, SG
FERRICK, K
ROTH, J
FURMAN, S
机构
[1] ALBERT EINSTEIN COLL MED,MONTEFIORE MED CTR,DEPT CARDIOTHORAC SURG,111 E 210TH ST,BRONX,NY 10467
[2] ALBERT EINSTEIN COLL MED,MONTEFIORE MED CTR,DEPT MED & ANESTHESIA,BRONX,NY 10467
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1993年 / 16卷 / 01期
关键词
NON-THORACOTOMY LEAD SYSTEM; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR;
D O I
10.1111/j.1540-8159.1993.tb01552.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction of non-thoracotomy lead systems'' (Medtronic, Inc.) for the implantable cardioverter defibrillator (ICD) has expanded the indications for use of this mode of therapy. Patients previously considered ''too ill'' to undergo a thoracotomy as well as patients who are at a high risk for developing sudden death but without previous cardiac arrest, are now considered candidates. The initial experience with the non-thoracotomy lead system at our institution was analyzed for morbidity and mortality. Thirty-four patients underwent attempted intravascular lead implantation, with 30 having initial successful implantation (88.2%). There were 23 males; average ejection fraction (EF) was 38.6%. Three patients developed pulmonary edema and low output immediately after the procedure. Three patients developed electromechanical dissociation during defibrillation threshold testing. A prolonged testing time for the non-thoracotomy lead system was noted when compared to the thoracotomy system (57.39 vs 32.30 min; P < 0.0000). There were more intraoperative morbidities with the non-thoracotomy leads than with the thoracotomy system. There were no perioperative deaths. The potential consequences of prolonged anesthesia time and extensive defibrillation threshold testing should be considered when choosing the route of ICD implant, the type of anesthesia, and the intraoperative testing protocol for each patient.
引用
收藏
页码:149 / 152
页数:4
相关论文
共 11 条
  • [1] TRANSVENOUS DEFIBRILLATION IN HUMANS VIA THE CORONARY SINUS
    BARDY, GH
    ALLEN, MD
    MEHRA, R
    JOHNSON, G
    FELDMAN, S
    GREENE, HL
    IVEY, TD
    [J]. CIRCULATION, 1990, 81 (04) : 1252 - 1259
  • [2] THE MANAGEMENT OF ELECTROMECHANICAL DISSOCIATION
    CRIPPS, T
    CAMM, J
    [J]. RESUSCITATION, 1991, 22 (02) : 173 - 180
  • [3] PHARMACOLOGICAL TREATMENT OF ASYSTOLE AND ELECTROMECHANICAL DISSOCIATION
    EVANS, TR
    MOGENSEN, L
    [J]. RESUSCITATION, 1991, 22 (02) : 167 - 172
  • [4] CLINICAL-EVALUATION OF THE SAFETY OF REPETITIVE INTRAOPERATIVE DEFIBRILLATION THRESHOLD TESTING
    FRAME, R
    BRODMAN, R
    FURMAN, S
    KIM, SG
    ROTH, J
    FERRICK, K
    HOLLINGER, I
    GROSS, J
    FISHER, JD
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (06): : 870 - 877
  • [5] IMPLANTABLE CARDIOVERTER DEFIBRILLATORS (ICD) - A NEW LEAD-SYSTEM USING TRANSVENOUS-SUBCUTANEOUS APPROACH IN PATIENTS WITH PRIOR CARDIAC-SURGERY
    HAMMEL, D
    BLOCK, M
    HACHENBERG, T
    BORGGREFE, M
    BUDDE, T
    SOEPARWATA, R
    KONERTZ, W
    HIEF, C
    GEYWITZ, HJ
    BREITHARDT, G
    SCHELD, HH
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1991, 5 (06) : 315 - 318
  • [6] EXACERBATION OF VENTRICULAR ARRHYTHMIAS DURING THE POSTOPERATIVE PERIOD AFTER IMPLANTATION OF AN AUTOMATIC DEFIBRILLATOR
    KIM, SG
    FISHER, JD
    FURMAN, S
    GROSS, J
    ZILO, P
    ROTH, JA
    FERRICK, KJ
    BRODMAN, R
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (05) : 1200 - 1206
  • [7] KIM SG, 1992, AM HEART ASS
  • [8] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IMPLANTATION WITHOUT THORACOTOMY USING AN ENDOCARDIAL AND SUBMUSCULAR PATCH SYSTEM
    MCCOWAN, R
    MALONEY, J
    WILKOFF, B
    SIMMONS, T
    KHOURY, D
    MCALISTER, H
    MORANT, V
    CASTLE, L
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (02) : 415 - 421
  • [9] INITIAL CLINICAL-EXPERIENCE WITH ENDOCARDIAL DEFIBRILLATION USING AN IMPLANTABLE CARDIOVERTER DEFIBRILLATOR WITH A TRIPLE-ELECTRODE SYSTEM
    SAKSENA, S
    TULLO, NG
    KROL, RB
    MAURO, AM
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1989, 149 (10) : 2333 - 2339
  • [10] MANAGEMENT OF COMPLICATIONS ASSOCIATED WITH A 1ST-GENERATION ENDOCARDIAL DEFIBRILLATION LEAD SYSTEM FOR IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS
    TULLO, NG
    SAKSENA, S
    KROL, RB
    MAURO, AM
    KUNECZ, D
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (04) : 411 - 415