The reliability of pocket probing around screw-type implants

被引:128
作者
Quirynen, M. [1 ]
van Steenberghe, D.
Jacobs, R.
Schotte, A.
Darius, P. [2 ]
机构
[1] Catholic Univ Louvain, Fac Med, Dept Periodontol, UZ St Raphael, B-3000 Louvain, Belgium
[2] Catholic Univ Louvain, Lab Stat & Expt Design, Fac Agr Sci, B-3001 Louvain, Belgium
关键词
osseointegration; oral implants; peri-impalntitis; pocket probing; soft tisse; radiology;
D O I
10.1034/j.1600-0501.1991.020405.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study involved 108 patients (age 38-82 years) rehabilated with overdentures in the lower jaw supported by 2 endosseous screw-shaped implants. At each follow-up visit, the clinical attachment level (PAL) around the implants was assessed with a Merrit-B probe or a constant force electronic probe, Peri-probe, and biannually parallel long-cone radiographs were taken to locate the marginal bone level. These data were used to locate the marginal bone level. These data were used to examine to relationship between bone and attachment level estimations around implants. As a mean, bone level was scored 1.4 mm apically of PAL and this difference remained constant with time. The Pearson correlation coefficient between bone level and PAL, for mesial and distal sites, was 0.67 and 0.61 for the Merrit-B probe, and 0.76 and 0.65, respectively for the Peri-probe. The highest correlations were obtained for sites with a healthy gingiva or in absence of intra-bony craters. Duplicate PAL registrators showed a standard deviation for the intra-examiner variability of 0.37 (Peri-probe) or 0.40 mm. The mean difference in PAL between Merrit-B probe or Peri-probe was 0.05 mm. It was concluded that the clinical attachment level determination is a relaible indicator for bone level around implants with a moderate healthy gingiva.
引用
收藏
页码:186 / 192
页数:7
相关论文
共 17 条
  • [1] Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
  • [2] [Anonymous], 1985, TISSUE INTEGRATED PR
  • [3] REPRODUCIBILITY OF PROBING ATTACHMENT LEVEL MEASUREMENTS
    BADERSTEN, A
    NILVEUS, R
    EGELBERG, J
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1984, 11 (07) : 475 - 485
  • [4] DESCRIPTION AND CLINICAL-EVALUATION OF A NEW COMPUTERIZED PERIODONTAL PROBE - THE FLORIDA PROBE
    GIBBS, CH
    HIRSCHFELD, JW
    LEE, JG
    LOW, SB
    MAGNUSSON, I
    THOUSAND, RR
    YERNENI, P
    CLARK, WB
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (02) : 137 - 144
  • [5] PATTERNS OF PROGRESSION AND REGRESSION OF ADVANCED DESTRUCTIVE PERIODONTAL-DISEASE
    GOODSON, JM
    TANNER, ACR
    HAFFAJEE, AD
    SORNBERGER, GC
    SOCRANSKY, SS
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1982, 9 (06) : 472 - 481
  • [6] COMPARISON OF DIFFERENT DATA ANALYSES FOR DETECTING CHANGES IN ATTACHMENT LEVEL
    HAFFAJEE, AD
    SOCRANSKY, SS
    GOODSON, JM
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1983, 10 (03) : 298 - 310
  • [7] RADIOGRAPHS IN CLINICAL PERIODONTAL TRIALS
    KELLY, GP
    CAIN, RJ
    KNOWLES, JW
    NISSLE, RR
    BURGETT, FG
    SHICK, RA
    RAMFJORD, SP
    [J]. JOURNAL OF PERIODONTOLOGY, 1975, 46 (07) : 381 - 386
  • [8] PERIODONTAL PROBING - WHAT DOES IT MEAN
    LISTGARTEN, MA
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1980, 7 (03) : 165 - 176
  • [9] Naert I, 1988, Int J Oral Maxillofac Implants, V3, P191
  • [10] Newman M G, 1988, J Dent Educ, V52, P737