EVALUATION OF A NITROGEN-COOLED, ELECTRICALLY HEATED COLD TRAP INLET FOR HIGH-SPEED GAS-CHROMATOGRAPHY

被引:31
作者
MOURADIAN, RF
LEVINE, SP
SACKS, RD
机构
[1] UNIV MICHIGAN,DEPT ENVIRONM & IND HLTH,ANN ARBOR,MI 48109
[2] UNIV MICHIGAN,DEPT CHEM,ANN ARBOR,MI 48109
关键词
Cold Trap Inlet - Gas Chromatography;
D O I
10.1093/chromsci/28.12.643
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Gas chromatography has the potential to be a much faster method of separation than is usually realized. If column operating conditions are optimized for speed and injection band width is minimized, some simple separations can be completed in a few seconds. A prototype cryofocusing system for producing narrow injection bands with 0.25-mm i.d. columns is described here. The gas-cooled and electrically heated inlet produces injection bands with widths of about 10-20 ms. In the present study the system is evaluated using mixtures of common organics, including alkanes, aromatics, alcohols, ketones, and chlorinated hydrocarbons. Quantitative trapping and reinjection is achieved for all tested compounds. Coefficients of variation are less than 3% for peak area and less than 0.2% for retention time. Base-line separation of simple mixture is achieved with retention times of less than 10 s. By using the cold trap inlet with a low-dead-volume detector and a high-speed electrometer, the efficiency available from commercial capillary columns can be better utilized, and retention times for some routine separations may be reduced to a few seconds. © 1990 Oxford University Press.
引用
收藏
页码:643 / 648
页数:6
相关论文
共 23 条
[1]   THE USE OF COANDA WALL ATTACHMENT FLUIDIC SWITCHES AS GAS-CHROMATOGRAPHIC VALVES [J].
ANNINO, R ;
LEONE, J .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1982, 20 (01) :19-26
[2]  
Desty D. H., 1962, GAS CHROMATOGRAPHY, P105
[3]  
DESTY DH, 1965, ADV CHROMATOGR, V1, P199
[4]   ELECTRICALLY HEATED COLD TRAP INLET SYSTEM FOR HIGH-SPEED GAS-CHROMATOGRAPHY [J].
EWELS, BA ;
SACKS, RD .
ANALYTICAL CHEMISTRY, 1985, 57 (14) :2774-2779
[5]   INFLUENCE OF INSTRUMENTAL CONTRIBUTIONS ON APPARENT COLUMN EFFICIENCY IN HIGH-SPEED GAS-CHROMATOGRAPHY [J].
GASPAR, G ;
ANNINO, R ;
VIDALMADJAR, C ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1978, 50 (11) :1512-1518
[6]   STUDY IN HIGH-SPEED GAS-CHROMATOGRAPHY .1. INJECTIONS OF NARROW SAMPLE PLUGS [J].
GASPAR, G ;
ARPINO, P ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1977, 15 (07) :256-261
[7]   HOW EFFICIENT ARE CAPILLARY COLD TRAPS [J].
GRAYDON, JW ;
GROB, K .
JOURNAL OF CHROMATOGRAPHY, 1983, 254 (JAN) :265-269
[8]   DEPENDENCE OF THE SPLITTING RATIO ON COLUMN TEMPERATURE IN SPLIT INJECTION CAPILLARY GAS-CHROMATOGRAPHY [J].
GROB, K ;
NEUKOM, HP .
JOURNAL OF CHROMATOGRAPHY, 1982, 236 (02) :297-306
[9]   RAPID EVAPORATION OF CONDENSED GAS-CHROMATOGRAPHIC FRACTIONS [J].
HOPKINS, BJ ;
PRETORIUS, V .
JOURNAL OF CHROMATOGRAPHY, 1978, 158 (OCT) :465-469
[10]   IMPROVEMENT OF SPEED OF SEPARATION IN PACKED-COLUMN GAS-CHROMATOGRAPHY [J].
JONKER, RJ ;
POPPE, H ;
HUBER, JFK .
ANALYTICAL CHEMISTRY, 1982, 54 (14) :2447-2456