VALIDATION OF ULTRAFAST COMPUTED TOMOGRAPHIC LEFT-VENTRICULAR VOLUME MEASUREMENT

被引:24
作者
PIETRAS, RJ
WOLFKIEL, CJ
VESELIK, K
ROIG, E
CHOMKA, EV
BRUNDAGE, BH
机构
[1] UNIV CALIF LOS ANGELES,LOS ANGELES CTY HARBOR MED CTR,DIV CARDIOL,1000 W CARSON ST,F-9,TORRANCE,CA 90509
[2] UNIV ILLINOIS,COLL MED,DEPT MED,CARDIOL SECT,CHICAGO,IL 60680
[3] ST JOHNS CARDIAC RES CTR,TORRANCE,CA
关键词
LEFT VENTRICULAR VOLUME; ULTRAFAST COMPUTED TOMOGRAPHY;
D O I
10.1097/00004424-199101000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Left ventricular volume has been measured with ultrafast computed tomography. However, the accuracy with which this can be done is unknown. We therefore imaged with ultrafast computed tomography 11 rectangular phantoms, 20 to 225 ml, and 17 left ventricular casts, 15 to 112 ml. Two observers planimetered serial tomographic images and computed volume from sequential tomograms. There was no significant inter- or intraobserver difference in measurement of phantoms. Deviation of ultrafast computed tomographic volume from true phantom volume was -0.1 +/- 3.5% SD, range 9.0 to -7.6%. Correlation of true phantom volume with ultrafast computed tomographic volume was 0.99, SEE = 1.9 ml. No significant difference was observed between merged and single ultrafast computed tomographic scanning sequences. Left ventricular cast volume determined by ultrafast computed tomography deviated from true volume by 6% +/- 20%, range 54% to -45%. Correlation of true volume with ultrafast computed tomographic volume was 0.99, SEE = 5.1 ml. There was no interobserver significant difference in measurement of left ventricular cast volume. Correlation between ultrafast computed tomographic volume and cineradiographic volume of the same left ventricular casts was 0.99, SEE = 4.4 ml. Thus, phantom volumes can be measured accurately without significant intra- or interobserver variation. Merged scanning sequences did not influence volume determination. Left ventricular cast volume determination was comparable to that obtained with cineradiography.
引用
收藏
页码:28 / 34
页数:7
相关论文
共 32 条
[1]   ANGIOGRAPHIC METHOD FOR VOLUME ESTIMATION OF RIGHT AND LEFT VENTRICLES [J].
ARCILLA, RA ;
TSAI, P ;
THILENIUS, O ;
RANNIGER, K .
CHEST, 1971, 60 (05) :446-+
[2]  
BOYD DP, 1987, AM J CARDIAC IMAGING, V1, P175
[3]  
BUNKER SR, 1985, AM J ROENTGENOL, V144, P295
[4]   MEASUREMENT OF LEFT-VENTRICULAR VOLUME USING SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY [J].
CAPUTO, GR ;
GRAHAM, MM ;
BRUST, KD ;
KENNEDY, JW ;
NELP, WB .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 56 (12) :781-786
[5]   TOMOGRAPHIC GATED BLOOD POOL RADIONUCLIDE VENTRICULOGRAPHY - ANALYSIS OF WALL MOTION AND LEFT-VENTRICULAR VOLUMES IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
CORBETT, JR ;
JANSEN, DE ;
LEWIS, SE ;
GABLIANI, GI ;
NICOD, P ;
FILIPCHUK, NG ;
REDISH, GA ;
AKERS, MS ;
WOLFE, CL ;
RELLAS, JS ;
PARKEY, RW ;
WILLERSON, JT .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (02) :349-358
[6]   AN ANALYSIS OF FIT OF MATHEMATICAL MODELS APPLICABLE TO MEASUREMENT OF LEFT VENTRICULAR VOLUME [J].
DAVILA, JC ;
SANMARCO, ME .
AMERICAN JOURNAL OF CARDIOLOGY, 1966, 18 (01) :31-&
[7]   DIRECT MEASUREMENT OF CARDIAC-OUTPUT BY GATED EQUILIBRIUM BLOOD POOL SCINTIGRAPHY - VALIDATION OF SCINTIGRAPHIC VOLUME MEASUREMENTS BY A NON-GEOMETRIC TECHNIQUE [J].
DEHMER, GJ ;
FIRTH, BG ;
LEWIS, SE ;
WILLERSON, JT ;
HILLIS, LD .
AMERICAN JOURNAL OF CARDIOLOGY, 1981, 47 (05) :1061-1067
[8]   THE USE OF BIPLANE ANGIOCARDIOGRAPHY FOR THE MEASUREMENT OF LEFT VENTRICULAR VOLUME IN MAN [J].
DODGE, HT ;
SANDLER, H ;
BALLEW, DW ;
LORD, JD .
AMERICAN HEART JOURNAL, 1960, 60 (05) :762-776
[9]  
FISCHER EA, 1975, AM J CARDIOL, V36, P67
[10]   SINGLE VERSUS BIPLANE RIGHT AND LEFT-VENTRICULAR VOLUMETRY - A CAST AND CLINICAL-STUDY [J].
FORMANEK, A ;
SCHEY, HM ;
EKSTRAND, KE ;
VELASQUEZ, G ;
DSOUZA, VJ ;
GLASS, TA .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1984, 10 (02) :137-156